Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Use of continuous glucose monitoring to stratify individuals without diabetes

Hikaru Sugimoto et al · Nature Portfolio · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Abstract Background Early detection of metabolic dysfunction before diabetes onset remains a critical challenge in preventive medicine. Although glucose dynamics provide high-dimensional insights into metabolic states, it remains unclear which combination of glucose dynamics-derived measures most effectively summarises interindividual differences in glucose regulation. Methods We analysed continuous glucose monitoring (CGM) data from 8025 adults without diagnosed diabetes, using all recordings of at least seven days’ duration, to derive a low-dimensional representation of glucose dynamics. Using exploratory factor analysis, we identified a small set of latent features that accounted for variation between individuals in CGM-derived metrics. We then trained and validated machine-learning models to predict postprandial glucose trajectories from these features in 863 participants who underwent standardised meal tests. We further assessed the generalisability of this representation in an independent oral glucose tolerance test dataset. Finally, we examined associations between the derived features and markers of vascular and liver health in 1784 non-diabetic adults. Results Three features, “mean”, “variance”, and “autocorrelation”, explain more than 80% of the interindividual differences in CGM-derived measures. A three-dimensional representation based on these features reconstructs postprandial glucose trajectories with high accuracy and outperforms fasting, mean, and two-hour postprandial glucose values. Each feature shows independent associations with carotid artery intima–media thickness and with hepatic steatosis and stiffness. Conclusions By compressing high-dimensional glucose dynamics into three interpretable features with minimal loss of information, this framework provides a simple yet physiologically meaningful representation of glucose regulation that may facilitate a more precise and interpretable assessment of diabetes-related risk.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, H. S. E. (2026). Use of continuous glucose monitoring to stratify individuals without diabetes. https://doi.org/10.1038/s43856-026-01523-8

MLA

al, Hikaru Sugimoto et. "Use of continuous glucose monitoring to stratify individuals without diabetes." 2026. https://doi.org/10.1038/s43856-026-01523-8.

Chicago

al, Hikaru Sugimoto et. 2026. "Use of continuous glucose monitoring to stratify individuals without diabetes.". https://doi.org/10.1038/s43856-026-01523-8.

Harvard

al, H. S. E. 2026, Use of continuous glucose monitoring to stratify individuals without diabetes, Nature Portfolio, available at: https://doi.org/10.1038/s43856-026-01523-8 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Use of continuous glucose monitoring to stratify individuals without diabetes
Autore / collaboratori
Hikaru Sugimoto et al
Editore
Nature Portfolio
Anno di pubblicazione
2026
ISSN
2730-664X
ISSN
2730-664X
Lingua
Inglés
Copiato