Descripción general del contenido del recurso.

Abstract Building energy consumption is dominated by lighting and heating, ventilation, and air conditioning (HVAC) systems, whose operation is often inefficient due to inadequate control strategies and unreliable occupancy detection. As occupancy patterns become increasingly dynamic, existing occupancy-based control models suffer from reduced robustness, particularly under variable occupant numbers and privacy constraints. This study addresses these limitations by proposing a privacy-preserving, multimodal occupancy detection framework that integrates direct sensing, ambient environmental sensing, and lighting-related parameters. An intelligent occupancy identification system based on a Random Forest (RF) classifier is developed to investigate how multimodal data fusion improves occupancy prediction accuracy and energy management performance. Parametric classification techniques are employed to analyze statistically significant relationships between occupancy states and sensor inputs. The optimized (RF), model achieves strong predictive performance, with accuracy, precision, recall, and F1-score values of 0.99, 1.00, 0.86, and 0.88, respectively. The optimized Random Forest model achieved an average testing accuracy of 90.6%, with recall, precision, and F1-score values of 0.86, 0.88, and 0.87, respectively, demonstrating robust predictive performance under variable occupancy conditions. Incorporating lighting data enhances model stability under varying occupancy conditions and enables adaptive control of HVAC and lighting systems, resulting in measurable energy savings. Overall, the results demonstrate that combining multimodal sensing with machine-learning-based modeling significantly improves occupancy prediction and supports intelligent building energy management. The proposed framework is applicable to real-time smart building systems and aligns with policy objectives aimed at reducing building energy consumption. Future work will extend the model to larger, more diverse datasets and multi-zone environments.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

Elhassan, Z. A. M. (2026). Building energy management through smart occupancy based control. https://doi.org/10.1007/s42452-026-08504-5

MLA

Elhassan, Zeinab Abdallah Mohammed. "Building energy management through smart occupancy based control." 2026. https://doi.org/10.1007/s42452-026-08504-5.

Chicago

Elhassan, Zeinab Abdallah Mohammed. 2026. "Building energy management through smart occupancy based control.". https://doi.org/10.1007/s42452-026-08504-5.

Harvard

Elhassan, Z. A. M. 2026, Building energy management through smart occupancy based control, Springer, available at: https://doi.org/10.1007/s42452-026-08504-5 [Accessed 23 Jun. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Building energy management through smart occupancy based control
Autor / colaboradores
Zeinab Abdallah Mohammed Elhassan
Editorial
Springer
Año de publicación
2026
ISSN
3004-9261
ISSN
3004-9261
Idioma
eng
Copiado