Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Building energy management through smart occupancy based control

Zeinab Abdallah Mohammed Elhassan · Springer · 2026

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Abstract Building energy consumption is dominated by lighting and heating, ventilation, and air conditioning (HVAC) systems, whose operation is often inefficient due to inadequate control strategies and unreliable occupancy detection. As occupancy patterns become increasingly dynamic, existing occupancy-based control models suffer from reduced robustness, particularly under variable occupant numbers and privacy constraints. This study addresses these limitations by proposing a privacy-preserving, multimodal occupancy detection framework that integrates direct sensing, ambient environmental sensing, and lighting-related parameters. An intelligent occupancy identification system based on a Random Forest (RF) classifier is developed to investigate how multimodal data fusion improves occupancy prediction accuracy and energy management performance. Parametric classification techniques are employed to analyze statistically significant relationships between occupancy states and sensor inputs. The optimized (RF), model achieves strong predictive performance, with accuracy, precision, recall, and F1-score values of 0.99, 1.00, 0.86, and 0.88, respectively. The optimized Random Forest model achieved an average testing accuracy of 90.6%, with recall, precision, and F1-score values of 0.86, 0.88, and 0.87, respectively, demonstrating robust predictive performance under variable occupancy conditions. Incorporating lighting data enhances model stability under varying occupancy conditions and enables adaptive control of HVAC and lighting systems, resulting in measurable energy savings. Overall, the results demonstrate that combining multimodal sensing with machine-learning-based modeling significantly improves occupancy prediction and supports intelligent building energy management. The proposed framework is applicable to real-time smart building systems and aligns with policy objectives aimed at reducing building energy consumption. Future work will extend the model to larger, more diverse datasets and multi-zone environments.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

Elhassan, Z. A. M. (2026). Building energy management through smart occupancy based control. https://doi.org/10.1007/s42452-026-08504-5

MLA

Elhassan, Zeinab Abdallah Mohammed. "Building energy management through smart occupancy based control." 2026. https://doi.org/10.1007/s42452-026-08504-5.

Chicago

Elhassan, Zeinab Abdallah Mohammed. 2026. "Building energy management through smart occupancy based control.". https://doi.org/10.1007/s42452-026-08504-5.

Harvard

Elhassan, Z. A. M. 2026, Building energy management through smart occupancy based control, Springer, available at: https://doi.org/10.1007/s42452-026-08504-5 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Building energy management through smart occupancy based control
Autore / collaboratori
Zeinab Abdallah Mohammed Elhassan
Editore
Springer
Anno di pubblicazione
2026
ISSN
3004-9261
ISSN
3004-9261
Lingua
Inglés
Copiato