← Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo

Efficient clinical workflow for intraoperative electron radiation therapy with a mobile electron accelerator

Deepak K. Shrestha et al · BMC · 2026

Acceso institucional disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

Acceso principal

Acceso institucional disponible

El acceso puede requerir institución, suscripción, proxy, VPN o autenticación.
Abrir acceso

Resumen

Descripción general del contenido del recurso.

Abstract Purpose Intraoperative radiotherapy (IORT) is designed to deliver a precise dose of ionizing radiation to a tumor or tumor bed after surgical resection. The IORT procedure can deliver targeted radiation to the tumor with increased normal tissue sparing, hence improving the efficacy of the procedure when nearby organs at risk (OAR) can be mobilized out of the field thus maximizing the therapeutic ratio. This report presents the institutional experience of establishing the IORT program, highlighting our workflow improvement, quality assurance (QA), and dosimetric practices. Methods The IntraOp® Mobetron® 2000 can be used to irradiate a target using megavoltage (MV) electron beams of energies 6 MeV, 9 MeV, and 12 MeV at a high dose rate of 1000 cGy/minute. Mayo Clinic Florida (MCF) has a dedicated and well-shielded QA suite adjacent to the operating room (OR) for both treatment preparation and daily QA purposes. The Mobetron is docked over the target assembly with the help of the autodocking software. The IORT workflow in the OR is assisted by the Mobility (IntraOp Medical Corp., Sunnyvale, CA) system which ensures safe and efficient maneuvering of the Mobetron. The treatment planning and beam control using the treatment console is done from inside the shielded QA room. Results Since its commissioning in 2016, 138 patients have been treated with IORT using the Mobetron ® 2000, at MCF. The efficacy of IORT has been utilized in the treatment of locally advanced and recurrent sites like pancreas, rectum, retroperitoneal sarcoma and some gynecologic cases. Conclusion A well-planned housing of the Mobetron, adjacent to the OR, and its timely upgrades has resulted in an efficient and safe IORT workflow.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, D. K. S. E. (2026). Efficient clinical workflow for intraoperative electron radiation therapy with a mobile electron accelerator. https://doi.org/10.1186/s13014-026-02831-y

MLA

al, Deepak K. Shrestha et. "Efficient clinical workflow for intraoperative electron radiation therapy with a mobile electron accelerator." 2026. https://doi.org/10.1186/s13014-026-02831-y.

Chicago

al, Deepak K. Shrestha et. 2026. "Efficient clinical workflow for intraoperative electron radiation therapy with a mobile electron accelerator.". https://doi.org/10.1186/s13014-026-02831-y.

Harvard

al, D. K. S. E. 2026, Efficient clinical workflow for intraoperative electron radiation therapy with a mobile electron accelerator, BMC, available at: https://doi.org/10.1186/s13014-026-02831-y [Accessed 29 Jun. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Efficient clinical workflow for intraoperative electron radiation therapy with a mobile electron accelerator
Autor / colaboradores
Deepak K. Shrestha et al
Editorial
BMC
Año de publicación
2026
ISSN
1748-717X
ISSN
1748-717X
Idioma
eng
Copiado