Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo de revista

Biomechanical evaluation of X-ray permeable CF/PEEK composite versus conventional titanium alloy for tibial external fixation plates: a finite element analysis

Shuaiyi Wang et al · Nature Portfolio · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

3D scan-based classification of Chinese young female hand morphology

Questa pubblicazione seriale contiene 688 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Abstract This study aimed to evaluate the mechanical performance of CF/PEEK composite plates for external fixation through finite element analysis (FEA), and to explore the impact of different screw placement patterns on fixation stability. A proximal tibial fracture model treated with external fixation was constructed using FEA. Longitudinal loading was applied to simulate walking stress, with additional internal and external rotational torques to mimic load-bearing movement. Mechanical responses of titanium alloy and CF/PEEK plates were compared under three loading conditions: longitudinal, longitudinal with internal rotation, and longitudinal with external rotation. Screw alignment was also varied between linear and non-linear configurations to assess its biomechanical influence. Compared to titanium alloy group, the linear CF/PEEK plate exhibited a mild increase in displacement of 0.232–0.386 mm (8.23–11.14%), accompanied by a substantial reduction in plate stress of 46.03–80.84%. At the fracture site, interfragmentary displacement increased slightly by 0.105–0.132 mm (5.56–6.74%), while fracture-site stress increased by 3.119–18.029 MPa (18.30–63.20%). The non-linear CF/PEEK plate demonstrated a similar biomechanical performance, with no significant differences compared with the linear configuration. For external plate fixation, CF/PEEK represents a promising alternative to conventional titanium alloy plates. By allowing an acceptable level of local micromotion, CF/PEEK plates significantly reduce stress in the plate and screws while increasing stress transfer at the fracture site. This load-sharing behavior may mitigate stress shielding associated with traditional metallic plates and thereby promote early biological fracture healing.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, S. W. E. (2026). Biomechanical evaluation of X-ray permeable CF/PEEK composite versus conventional titanium alloy for tibial external fixation plates: a finite element analysis. https://doi.org/10.1038/s41598-026-43182-8

MLA

al, Shuaiyi Wang et. "Biomechanical evaluation of X-ray permeable CF/PEEK composite versus conventional titanium alloy for tibial external fixation plates: a finite element analysis." 2026. https://doi.org/10.1038/s41598-026-43182-8.

Chicago

al, Shuaiyi Wang et. 2026. "Biomechanical evaluation of X-ray permeable CF/PEEK composite versus conventional titanium alloy for tibial external fixation plates: a finite element analysis.". https://doi.org/10.1038/s41598-026-43182-8.

Harvard

al, S. W. E. 2026, Biomechanical evaluation of X-ray permeable CF/PEEK composite versus conventional titanium alloy for tibial external fixation plates: a finite element analysis, Nature Portfolio, available at: https://doi.org/10.1038/s41598-026-43182-8 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Biomechanical evaluation of X-ray permeable CF/PEEK composite versus conventional titanium alloy for tibial external fixation plates: a finite element analysis
Autore / collaboratori
Shuaiyi Wang et al
Editore
Nature Portfolio
Anno di pubblicazione
2026
ISSN
2045-2322
ISSN
2045-2322
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato