← Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo

Automated high-throughput quantification of plasma p-tau217 and APOE-ε4 for Alzheimer’s disease diagnosis and cognitive decline in a memory cohort

Jochen Titeca et al · BMC · 2026

Acceso abierto disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

Acceso principal

Acceso abierto disponible

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Abrir recurso

Resumen

Descripción general del contenido del recurso.

Abstract Background Blood-based biomarkers could improve the precision of Alzheimer’s disease (AD) clinical diagnosis and expand access to targeted treatments. Therefore, we evaluated the diagnostic accuracy of plasma Elecsys p-tau217 (Roche) and compared it with Elecsys p-tau181 (Roche) and Lumipulse p-tau217 (Fujirebio). We also assessed the added value of APOE-ε4 carrier status, plasma Aβ42 and Aβ42/40 in a memory-clinic cohort and evaluated associations with longitudinal cognition. Materials and methods A total of 187 patients from the Cognitive Centre Ghent University (CCUG) biobank, classified as AD (n = 103) or non-AD cognitive disorders (n = 84) based on CSF biomarkers (CSF Aβ42/40 ratio, total tau and p-tau181), were included. Plasma Elecsys p-tau181, p-tau217, and APOE-ε4 were measured on the Roche cobas® pro e801, and p-tau217, Aβ42, and Aβ40 on the Fujirebio LUMIPULSE G1200. ROC analyses and single- and two-cut-off strategies (95% sensitivity/specificity) were applied. Subgroup analyses examined APOE-ε4 status, renal function, cerebral amyloid angiopathy (CAA) features, Fazekas score, and longitudinal cognition. Results Elecsys plasma p-tau217 showed high discriminative performance for AD versus non-AD (AUC 0.939), comparable to Lumipulse p-tau217 (AUC 0.950; p = 0.485). Elecsys p-tau181 performed lower than Elecsys p-tau217 (AUC 0.903; p = 0.043). Using a two-cut-off strategy, the intermediate proportion was 19.9% for Elecsys p-tau217, 11.9% for Lumipulse p-tau217, and 33.2% for Elecsys p-tau181. Adding APOE-ε4 to Elecsys p-tau217 improved discriminative performance (AUC 0.970, p = 0.02) and reduced intermediates to 11.0%. Adjustment for Aβ42 on the Fujirebio platform did not significantly increase the AUC (0.950 vs. 0.957; p = 0.322) and modestly reduced intermediate classifications (11.9% to 10.0%). Higher baseline Elecsys p-tau217 was associated with lower baseline MoCA and a trend towards faster MoCA decline (p = 0.07). Age, sex, renal function, Fazekas score, and CAA were not significantly associated with Elecsys p-tau217 concentrations. Conclusion Plasma Elecsys p-tau217 measured on an automated high-throughput platform shows excellent diagnostic accuracy for AD. Incorporating APOE-ε4 further improves classification, while Aβ42 adjustment had only limited additional impact. Baseline p-tau217 also reflects cognitive severity and may relate to subsequent cognitive decline in the memory-clinic setting.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, J. T. E. (2026). Automated high-throughput quantification of plasma p-tau217 and APOE-ε4 for Alzheimer’s disease diagnosis and cognitive decline in a memory cohort. https://doi.org/10.1186/s13195-026-01996-8

MLA

al, Jochen Titeca et. "Automated high-throughput quantification of plasma p-tau217 and APOE-ε4 for Alzheimer’s disease diagnosis and cognitive decline in a memory cohort." 2026. https://doi.org/10.1186/s13195-026-01996-8.

Chicago

al, Jochen Titeca et. 2026. "Automated high-throughput quantification of plasma p-tau217 and APOE-ε4 for Alzheimer’s disease diagnosis and cognitive decline in a memory cohort.". https://doi.org/10.1186/s13195-026-01996-8.

Harvard

al, J. T. E. 2026, Automated high-throughput quantification of plasma p-tau217 and APOE-ε4 for Alzheimer’s disease diagnosis and cognitive decline in a memory cohort, BMC, available at: https://doi.org/10.1186/s13195-026-01996-8 [Accessed 29 Jun. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Automated high-throughput quantification of plasma p-tau217 and APOE-ε4 for Alzheimer’s disease diagnosis and cognitive decline in a memory cohort
Autor / colaboradores
Jochen Titeca et al
Editorial
BMC
Año de publicación
2026
ISSN
1758-9193
ISSN
1758-9193
Idioma
eng

Materias

Explorá otros recursos relacionados a partir de estas materias.

Copiado