Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Assessment of automated loop-mediated isothermal amplification-(LAMP-)based xenomonitoring for Plasmodium spp. in Anopheles mosquitoes

Albert Eisenbarth et al · BMC · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Abstract Background Xenomonitoring is an approach of epidemiological infection risk assessment addressing vector-transmitted infections like malaria in hematophagous arthropods. Standardization and automation can facilitate its use even in remote areas. In this study, the suitability of an automated commercial loop-mediated isothermal amplification (LAMP) assay, originally designed for the detection of malaria parasite DNA in human blood, was assessed for its applicability for xenomonitoring purposes. Methods An automated generic LAMP assay for malaria detection in human blood was applied with Anopheles spp. samples. The results were compared with commercial generic as well as species-specific real-time PCR. Results LAMP identified 15/43 (34.9%, 95% CI (20.1%; 50.9%)) mosquitoes artificially exposed to Plasmodium berghei, while this was the case for 22/43 (51.2%, 95% CI (35.5%; 66.7%)) samples applying real-time PCR. Considerably less discrepancy was observed with Anopheles spp. imported to Germany from field studies with 12/172 pools (7.0%, 95% CI (3.7%; 11.9%)) for LAMP and 13/172 pools (7.6%, 95% CI (4.1%; 12.6%)) for real-time PCR. Single testing and typing of DNA isolates indicated an overall infection rate of 1.2% (20/1711) with Plasmodium falciparum, P. malariae and P. ovale. Low rates of invalid results during a field exercise proved the general suitability of the LAMP approach for use at tropical settings. Conclusions Imperfect sensitivity in case of artificial exposure of mosquitoes to non-human plasmodial species was detected for both compared molecular approaches with slightly lower sensitivity of the LAMP approach. For Anopheles spp. infected with Plasmodium spp. causing human malaria, comparable diagnostic reliability could be shown for both approaches and the LAMP assay was shown to be suitable for application under tropical field conditions.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, A. E. E. (2026). Assessment of automated loop-mediated isothermal amplification-(LAMP-)based xenomonitoring for Plasmodium spp. in Anopheles mosquitoes. https://doi.org/10.1186/s12936-026-05917-w

MLA

al, Albert Eisenbarth et. "Assessment of automated loop-mediated isothermal amplification-(LAMP-)based xenomonitoring for Plasmodium spp. in Anopheles mosquitoes." 2026. https://doi.org/10.1186/s12936-026-05917-w.

Chicago

al, Albert Eisenbarth et. 2026. "Assessment of automated loop-mediated isothermal amplification-(LAMP-)based xenomonitoring for Plasmodium spp. in Anopheles mosquitoes.". https://doi.org/10.1186/s12936-026-05917-w.

Harvard

al, A. E. E. 2026, Assessment of automated loop-mediated isothermal amplification-(LAMP-)based xenomonitoring for Plasmodium spp. in Anopheles mosquitoes, BMC, available at: https://doi.org/10.1186/s12936-026-05917-w [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Assessment of automated loop-mediated isothermal amplification-(LAMP-)based xenomonitoring for Plasmodium spp. in Anopheles mosquitoes
Autore / collaboratori
Albert Eisenbarth et al
Editore
BMC
Anno di pubblicazione
2026
ISSN
1475-2875
ISSN
1475-2875
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato