Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Next-Generation SCS Programming Platform: Enhancing ECAP Fidelity and Objectivity to Improve Patient Experience

Daniel J. Parker et al · Adis, Springer Healthcare · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Abstract Introduction Evoked compound action potentials (ECAPs) are neurophysiological biomarkers of neural activation during spinal cord stimulation (SCS). Clear distinction between ECAPs and nonphysiological signals is critical to the application of contemporary, ECAP-based closed-loop (CL) SCS therapies. Herein, we evaluated the performance and user acceptability of a novel programming software that automates generation of ECAP-based CL-SCS programs—the Assisted Programming Module (APM). Methods We report results from two prospective, multicenter, single-arm, feasibility studies: Freshwater (NCT04662905) and Rosella (NCT06057480). APM performance was compared with the previous generation programming software and other published methods. Performance was assessed by comparing signal-to-noise ratios, artifact rejection, and other objective parameters. User acceptability was assessed using questionnaires administered to SCS users. Results The APM successfully generated a CL program in 96% of initial programming sessions (n = 81/84; Freshwater, 31/34; Rosella, 50/50). In the Rosella study, median time to generate an automated CL program (n = 68) was 11.9 min [interquartile range (IQR) 9.9–14.0]. Median dose ratio was 1.31 (IQR 1.20–1.46) at end of trial (n = 24), 1.34 (IQR 1.13–1.51) at 1 month post implant (n = 16), and 1.32 (IQR 1.21–1.48) at 3 months post implant (n = 15). At least 90% of patients [trial, 90% (27/30); implant, 94% (17/18)] were satisfied with their programming experience, and ≥ 90% of patients [trial, 90% (26/29); implant, 94% (16/17)] felt in control of their therapy. The APM achieved a mean signal-to-noise ratio of 4.6 ± 1.2, a 35% improvement over the previous generation ECAP dose-controlled CL-SCS system. Detectable artifact leakage rates decreased by 75% when compared with other published methods without compromise to signal-to-noise performance. Conclusions Next-generation ECAP dose-controlled CL technology demonstrated strong feasibility, high patient satisfaction and therapy control, and superior ECAP signal fidelity compared with existing methods. By standardizing CL-SCS programming and enhancing signal fidelity, the APM may improve workflow efficiency and long-term therapy outcomes in chronic pain management. Trial Registration ClinicalTrials.gov identifiers: NCT04662905, NCT06057480.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, D. J. P. E. (2026). Next-Generation SCS Programming Platform: Enhancing ECAP Fidelity and Objectivity to Improve Patient Experience. https://doi.org/10.1007/s40122-025-00808-5

MLA

al, Daniel J. Parker et. "Next-Generation SCS Programming Platform: Enhancing ECAP Fidelity and Objectivity to Improve Patient Experience." 2026. https://doi.org/10.1007/s40122-025-00808-5.

Chicago

al, Daniel J. Parker et. 2026. "Next-Generation SCS Programming Platform: Enhancing ECAP Fidelity and Objectivity to Improve Patient Experience.". https://doi.org/10.1007/s40122-025-00808-5.

Harvard

al, D. J. P. E. 2026, Next-Generation SCS Programming Platform: Enhancing ECAP Fidelity and Objectivity to Improve Patient Experience, Adis, Springer Healthcare, available at: https://doi.org/10.1007/s40122-025-00808-5 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Next-Generation SCS Programming Platform: Enhancing ECAP Fidelity and Objectivity to Improve Patient Experience
Autore / collaboratori
Daniel J. Parker et al
Editore
Adis, Springer Healthcare
Anno di pubblicazione
2026
ISSN
2193-8237
ISSN
2193-8237
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato