Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Design of a fixture for precise perpendicular cuts in bone-implant sample preparation

Mihail Genchev et al · BMC · 2026

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Abstract Accurate specimen preparation is essential for biomechanical push-out testing of bone–implant interfaces. A common source of error arises when implants such as pins or screws are not cut exactly perpendicular to their axis. This results in oval or irregular cross-sections that compromise the validity of mechanical testing. In this study, we present a newly developed holder designed to ensure perpendicular sectioning of bone-anchored implants. Titanium pins coated with tricalcium phosphate (TCP) and GB14 were implanted in rabbit condyles and prepared for thin-section analysis using the Donath method. The roundness of implant cross-sections was quantitatively assessed with ImageJ (FIJI 1.53t) based on circularity and aspect ratio parameters. Compared with conventional freehand sectioning techniques, which exhibited a roundness of 0.83 ± 0.06 and an aspect ratio of 1.22 ± 0.09, the novel holder achieved markedly improved geometrical accuracy, with a roundness of 0.99 ± 0.002 and an aspect ratio of 1.003 ± 0.002. This difference was statistically significant (p < 0.01). These results demonstrate that the device effectively minimizes geometric artifacts during sample preparation, thereby enhancing reproducibility and reliability in subsequent biomechanical testing. Although the validation was limited to rabbit condyles, the holder is a simple and versatile instrument with the potential for application across different implant types and experimental models.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, M. G. E. (2026). Design of a fixture for precise perpendicular cuts in bone-implant sample preparation. https://doi.org/10.1186/s13104-026-07813-7

MLA

al, Mihail Genchev et. "Design of a fixture for precise perpendicular cuts in bone-implant sample preparation." 2026. https://doi.org/10.1186/s13104-026-07813-7.

Chicago

al, Mihail Genchev et. 2026. "Design of a fixture for precise perpendicular cuts in bone-implant sample preparation.". https://doi.org/10.1186/s13104-026-07813-7.

Harvard

al, M. G. E. 2026, Design of a fixture for precise perpendicular cuts in bone-implant sample preparation, BMC, available at: https://doi.org/10.1186/s13104-026-07813-7 [Accessed 10 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Design of a fixture for precise perpendicular cuts in bone-implant sample preparation
Autore / collaboratori
Mihail Genchev et al
Editore
BMC
Anno di pubblicazione
2026
ISSN
1756-0500
ISSN
1756-0500
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato