← Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo

Improving retrospective ARDS case-finding using a simple 72-h physiologic persistence rule

Dominic C. Marshall et al · SpringerOpen · 2026

Material complementario disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

Acceso principal

Material complementario disponible

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Abrir material

Resumen

Descripción general del contenido del recurso.

Abstract Background Retrospective studies frequently use single-time-point Berlin physiologic criteria (PaO2/FiO2 < 300 mm Hg plus positive end-expiratory pressure ≥ 5 cm H2O) to identify acute respiratory distress syndrome (ARDS). However, transient hypoxaemia is common among critically ill patients and often does not represent ARDS. Using these screens may overestimate ARDS prevalence and yield a cohort inconsistent with those seen in clinical trials. We sought to determine whether a 72-h persistence criterion for hypoxaemia improves the accuracy of ARDS case identification and evaluate the additional case-finding value of radiology keyword searches and ICD-codes. Methods We conducted a retrospective cohort study using the MIMIC-IV database (2008–2019) for derivation and a UK ICU dataset (Imperial College Healthcare National Health Service Trust, 2009–2024) for external validation. All patients meeting Berlin physiologic criteria for at least 72 h were identified. From MIMIC-IV, we randomly selected 2000 patients who met 72-h persistence criteria for expert adjudication based on detailed review of clinical notes, imaging, and echocardiography, classifying them as ARDS, non-ARDS acute hypoxaemic respiratory failure, or possible ARDS. Sensitivity analyses with shorter durations (≥ 24 and ≥ 48 h) were performed. Diagnostic performance of radiology keyword searches and ARDS-specific ICD-9/10 codes were compared to expert adjudication. Results Of 18,621 patients who ever met physiologic criteria, 3940 met the 72-h persistence threshold. In a random sample of 2000 from this 72-h MIMIC-IV cohort, expert adjudication identified ARDS in 49.7% (95% CI, 48–52%); in the external UK validation cohort, 56% (95% CI, 46–66%) were adjudicated as ARDS. ARDS prevalence significantly declined with shorter persistence requirements: 21% after 48 h, 8% after 24 h, and 6% with single isolated measurements. Within the 72-h persistence criterion enriched sample, the highest performing radiology keyword search set provided limited sensitivity (49%) and moderate specificity (76%), whereas ICD codes had higher sensitivity (76%) but low specificity (47%). Conclusions Berlin physiologic criteria alone were inadequate for retrospective ARDS identification. A ≥ 72-h persistence rule improved cohort enrichment but did not define ARDS, with substantial residual misclassification remaining after physiologic screening. Persistence should therefore be viewed as a pragmatic enrichment strategy rather than a definitive retrospective ARDS label.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, D. C. M. E. (2026). Improving retrospective ARDS case-finding using a simple 72-h physiologic persistence rule. https://doi.org/10.1186/s40635-026-00901-9

MLA

al, Dominic C. Marshall et. "Improving retrospective ARDS case-finding using a simple 72-h physiologic persistence rule." 2026. https://doi.org/10.1186/s40635-026-00901-9.

Chicago

al, Dominic C. Marshall et. 2026. "Improving retrospective ARDS case-finding using a simple 72-h physiologic persistence rule.". https://doi.org/10.1186/s40635-026-00901-9.

Harvard

al, D. C. M. E. 2026, Improving retrospective ARDS case-finding using a simple 72-h physiologic persistence rule, SpringerOpen, available at: https://doi.org/10.1186/s40635-026-00901-9 [Accessed 29 Jun. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Improving retrospective ARDS case-finding using a simple 72-h physiologic persistence rule
Autor / colaboradores
Dominic C. Marshall et al
Editorial
SpringerOpen
Año de publicación
2026
ISSN
2197-425X
ISSN
2197-425X
Idioma
eng

Materias

Explorá otros recursos relacionados a partir de estas materias.

Copiado