Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Fluorescence Quenching of the Fluorophore Diphenylamine for Determination of Neodymium (III)

Tara F. Tahir · Koya University · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Advanced analytical techniques such as Inductively Coupled Plasma Mass Spectrometry (ICP-MS) are powerful tools for chemical analysis; however, they present several practical challenges, including high operating costs, the need for skilled personnel, and time-consuming procedures for analysis and data interpretation. Their performance can also be affected by sample matrix interference, limited throughput, strict calibration requirements, and environmental concerns related to hazardous solvent disposal. Therefore, the development of a simple, sensitive, and cost-effective method such as fluorometry is highly desirable. In this study, fluorometry was applied for the determination of neodymium (III) based on the quenching mechanism of the fluorescent agent diphenylamine (DPA) in an ethanol medium. Neodymium, a lanthanide element, is important due to its environmental, industrial, and technological impacts. The fluorescence signal of DPA, excited at 310 nm, is quenched by Nd(III) in the presence of 2.2 mL of Britton–Robinson buffer at pH 3.0, forming a stable ion-associated complex. The method showed linearity over the concentration range of 0.5–24.0 μg/mL, with a limit of detection of 0.046 μg/mL and a limit of quantification of 0.140 μg/mL, and a strong correlation coefficient (R² = 0.9956). The tolerance of common coexisting substances was evaluated, and the results were consistent with those obtained using ICP-MS, confirming the method’s accuracy and precision, indicating that it is a reliable, simple, and effective tool for environmental monitoring and analysis.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

Tahir, T. F. (2026). Fluorescence Quenching of the Fluorophore Diphenylamine for Determination of Neodymium (III). https://doi.org/10.14500/aro.12870

MLA

Tahir, Tara F. "Fluorescence Quenching of the Fluorophore Diphenylamine for Determination of Neodymium (III)." 2026. https://doi.org/10.14500/aro.12870.

Chicago

Tahir, Tara F. 2026. "Fluorescence Quenching of the Fluorophore Diphenylamine for Determination of Neodymium (III).". https://doi.org/10.14500/aro.12870.

Harvard

Tahir, T. F. 2026, Fluorescence Quenching of the Fluorophore Diphenylamine for Determination of Neodymium (III), Koya University, available at: https://doi.org/10.14500/aro.12870 [Accessed 9 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Fluorescence Quenching of the Fluorophore Diphenylamine for Determination of Neodymium (III)
Autore / collaboratori
Tara F. Tahir
Editore
Koya University
Anno di pubblicazione
2026
ISSN
2410-9355
ISSN
2410-9355
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato