Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Heat and mass transfer in the semi-underground double-storey squat silo: a numerical analysis during static grain storage

Libing Jin et al · Elsevier · 2026

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

The semi-underground double-storey squat silo (SDSS) is innovative storage structure. The underground section of SDSS uses shallow geologic energy for low-temperature storage, indicating its potential suitability for long-term grain storage under appropriate insulation and management conditions. The above-ground section of the SDSS has a high efficiency storage and transit functions. Two important elements influencing the safety of stored grain are temperature and relative humidity (T-RH) in a grain pile. Using conservation equations, a mathematical model of T-RH flow in the grain pile has been generated in order to examine the spatiotemporal evolution of T-RH in the SDSS. The model's validity was confirmed through experiments. Meanwhile, a T-RH transfer model was further developed for the static grain storage process in a SDSS, and the spatiotemporal distribution patterns of T-RH in the grain pile were analyzed. The results revealed: 1) Seasonal fluctuations have a significant impact on the grain pile temperature (GT) changes in the above-ground section and the upper air of the SDSS. 2) As the external climate changes, the T-RH of the peripheral zone of the above-ground grain pile show an approximate negative correlation. 3) The GT changes of the above-ground storey are related to the initial GT and environmental conditions. 4) The GT changes of the underground storey are significantly influenced by the constant environmental GT. The findings provide useful insights into the temperature–humidity evolution characteristics in SDSS and offer a reference for further research and optimization of SDSS design.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, L. J. E. (2026). Heat and mass transfer in the semi-underground double-storey squat silo: a numerical analysis during static grain storage. https://doi.org/10.1016/j.csite.2026.108124

MLA

al, Libing Jin et. "Heat and mass transfer in the semi-underground double-storey squat silo: a numerical analysis during static grain storage." 2026. https://doi.org/10.1016/j.csite.2026.108124.

Chicago

al, Libing Jin et. 2026. "Heat and mass transfer in the semi-underground double-storey squat silo: a numerical analysis during static grain storage.". https://doi.org/10.1016/j.csite.2026.108124.

Harvard

al, L. J. E. 2026, Heat and mass transfer in the semi-underground double-storey squat silo: a numerical analysis during static grain storage, Elsevier, available at: https://doi.org/10.1016/j.csite.2026.108124 [Accessed 10 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Heat and mass transfer in the semi-underground double-storey squat silo: a numerical analysis during static grain storage
Autore / collaboratori
Libing Jin et al
Editore
Elsevier
Anno di pubblicazione
2026
ISSN
2214-157X
ISSN
2214-157X
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato