Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo de revista

Long-Term Stability of the Use of Patient Specific Implants in Orthognathic Surgery: A Systematic Review

Aaron Wu et al · Elsevier · 2026

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A Comparative Study of Caerin 1.1/1.9 and Calcium Hydroxide in the Treatment of Apical Periodontitis in Rats

Questa pubblicazione seriale contiene 111 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

ABSTRACT: Introduction and aim: This systematic review aimed to evaluate the long-term stability of patient-specific implants (PSIs) in orthognathic surgery. Methods: The review was conducted based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. A systematic search including an electronic search of numerous databases with keywords, manual and reference searches was performed. The search results were evaluated and underwent 2 rounds of elimination, first by title and abstract and second by fulfilling the 6 predetermined criteria. The included studies underwent the final systematic review. Results: Six studies with a total of 171 subjects were included in the final review. The long-term stability of the use of PSIs in orthognathic surgery ranged from 0.27 mm to 0.5 mm for the x-axis and 0.3 mm to 1.07 mm for the y-axis. The mean change was 0.1°, 0.5° and 0.2° for the pitch, roll and yaw, respectively. The absolute mean difference of the SNA angle was 0.57°. The mean duration of operation for using PSIs was shorter than the use of conventional miniplates in orthognathic surgery by 15.7%. Complications and reoperation rates when using PSIs in orthognathic surgery were reported to be 0 in 3 studies and not reported in the other 3 studies. Conclusion: The results of this systematic review indicate that PSIs demonstrate clinically acceptable stability over the medium-to-long term and represent a reliable method of fixation in orthognathic surgery. Additional high-quality studies with standardised methodology and longer follow-up period of more than 24 months are recommended. Clinical relevance: This systematic review highlights the high level of long-term stability when using PSIs in orthognathic surgery in terms of bodily movements, complications and reoperation rates. Oral and maxillofacial surgeons and biomechanical engineers may now have a more comprehensive and deeper understanding of the use of PSIs in the long term, which can assist them in choosing the method of fixation in orthognathic surgery.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, A. W. E. (2026). Long-Term Stability of the Use of Patient Specific Implants in Orthognathic Surgery: A Systematic Review. https://doi.org/10.1016/j.identj.2026.109503

MLA

al, Aaron Wu et. "Long-Term Stability of the Use of Patient Specific Implants in Orthognathic Surgery: A Systematic Review." 2026. https://doi.org/10.1016/j.identj.2026.109503.

Chicago

al, Aaron Wu et. 2026. "Long-Term Stability of the Use of Patient Specific Implants in Orthognathic Surgery: A Systematic Review.". https://doi.org/10.1016/j.identj.2026.109503.

Harvard

al, A. W. E. 2026, Long-Term Stability of the Use of Patient Specific Implants in Orthognathic Surgery: A Systematic Review, Elsevier, available at: https://doi.org/10.1016/j.identj.2026.109503 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Long-Term Stability of the Use of Patient Specific Implants in Orthognathic Surgery: A Systematic Review
Autore / collaboratori
Aaron Wu et al
Editore
Elsevier
Anno di pubblicazione
2026
ISSN
0020-6539
ISSN
0020-6539
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato