← Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo de revista

Influence of clinical setting and cat characteristics on indirectly measured blood pressure and pulse rate in healthy Birman, Norwegian Forest, and Domestic Shorthair cats

Sofia Hanås et al · Oxford University Press · 2021

Material complementario disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.
Publicación seriada

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

Esta publicación seriada contiene 149 contenidos relacionados.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

Acceso principal

Material complementario disponible

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Abrir material

Resumen

Descripción general del contenido del recurso.

Abstract Background Measured indirect blood pressure (BP) results in cats in a clinical environment might be affected by stress and characteristics of the cats. Hypothesis To investigate the influence of clinical setting, cat characteristics, and life situation on BP and pulse rate (PR) in healthy cats. Animals Ninety‐four healthy Domestic Shorthair, Birman and Norwegian Forest cats. Methods Blood pressure measured by high‐definition oscillometry in 3 settings: cat placed in its own carrier with veterinarian present; cat placed in carrier with owner alone present; and cat placed on table with veterinarian present. Statistical analyses were performed using mixed linear models. Results Systolic BP (SBP) did not differ among settings. Higher mean arterial pressure (MAP), diastolic BP (DBP), and PR were found when measurements were performed with cat placed on table, rather than in carrier. Coefficients of variation (CVs) higher for SBP, MAP, DBP, and PR when measured with cat placed on table than in carrier. Birman cats had lower BP than other breeds. Systolic BP, MAP, DBP, and PR increased with age. Cats allowed outdoors had lower PR than cats living strictly indoors. Conclusion and Clinical Importance No difference in SBP was found among settings, but measuring BP with the cat placed on the examination table gave higher MAP, DBP, PR, and CV than measuring BP with the cat in its carrier. Breed affected BP, with lower BP in Birman cats than other breeds. Blood pressure increased with age. Pulse rate was lower in cats allowed outdoors than cats living strictly indoors.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, S. H. E. (2021). Influence of clinical setting and cat characteristics on indirectly measured blood pressure and pulse rate in healthy Birman, Norwegian Forest, and Domestic Shorthair cats. https://doi.org/10.1111/jvim.16096

MLA

al, Sofia Hanås et. "Influence of clinical setting and cat characteristics on indirectly measured blood pressure and pulse rate in healthy Birman, Norwegian Forest, and Domestic Shorthair cats." 2021. https://doi.org/10.1111/jvim.16096.

Chicago

al, Sofia Hanås et. 2021. "Influence of clinical setting and cat characteristics on indirectly measured blood pressure and pulse rate in healthy Birman, Norwegian Forest, and Domestic Shorthair cats.". https://doi.org/10.1111/jvim.16096.

Harvard

al, S. H. E. 2021, Influence of clinical setting and cat characteristics on indirectly measured blood pressure and pulse rate in healthy Birman, Norwegian Forest, and Domestic Shorthair cats, Oxford University Press, available at: https://doi.org/10.1111/jvim.16096 [Accessed 29 Jun. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Influence of clinical setting and cat characteristics on indirectly measured blood pressure and pulse rate in healthy Birman, Norwegian Forest, and Domestic Shorthair cats
Autor / colaboradores
Sofia Hanås et al
Editorial
Oxford University Press
Año de publicación
2021
ISSN
0891-6640
ISSN
0891-6640
Idioma
eng

Materias

Explorá otros recursos relacionados a partir de estas materias.

Copiado