← Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo de revista

Biópsia de fragmento em nódulos mamários suspeitos com até 10 mm Core biopsy in suspicious solid breast lesions up to 10 mm

Hélio Sebastião Amâncio de Camargo Júnior et al · Federação Brasileira das Sociedades de Ginecologia e Obstetrícia · 2007

Material complementario disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.
Publicación seriada

A FEBRASGO e o Novo Ano

Esta publicación seriada contiene 195 contenidos relacionados.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

Acceso principal

Material complementario disponible

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Abrir material

Resumen

Descripción general del contenido del recurso.

OBJETIVO: avaliar a eficácia diagnóstica da biópsia de fragmento em nódulos mamários suspeitos (Bi-Rads® 4 ou 5) de até 10 mm. MÉTODOS: o estudo foi realizado em 83 mulheres portadoras de 90 nódulos mamários suspeitos, diagnosticados por mamografia (41 nódulos), ultra-sonografia (47 nódulos) ou palpação (dois nódulos), que estiveram em nossa clínica no período de setembro de 2003 a janeiro de 2006. O critério de inclusão foi unicamente o tamanho dos nódulos, que não poderia passar de 1 cm. Os nódulos foram biopsiados com dispositivo automático (pistola Bard, Corington, GA) com agulha de calibre 14, todos guiados pela ultra-sonografia. De acordo com a análise do seu resultado, as biópsias foram classificadas em verdadeiros-positivos, falsos-positivos, verdadeiros-negativos e falsos-negativos. Foram então calculadas a sensibilidade e a especificidade da biópsia de fragmento dirigida por ultra-sonografia realizada em nódulos de até 1 cm. RESULTADOS: a média de idade das mulheres foi de 52,8 anos e o diâmetro médio dos nódulos foi de 7,3 mm, sendo o maior de 10 mm e o menor de 3 mm. Os resultados das biópsias mostraram 40 casos benignos (44,4%); 49 casos malignos (54,4%) e um caso (1,2%) de material considerado inconclusivo. Essa paciente foi submetida à nova biópsia de fragmento sob controle ultra-sonográfico, dessa vez obtendo-se material conclusivo. Houve concordância entre os achados anatomopatológicos e imagenológicos em 89 dos casos. A sensibilidade da biópsia de fragmento para o diagnóstico do câncer de mama foi de 98,8% e a especificidade foi de 100%. CONCLUSÕES: os resultados obtidos pela biópsia de fragmento guiada pela ultra-sonografia em nódulos sólidos de até 10 mm nesse trabalho são semelhantes aos melhores resultados de qualquer tipo de biópsia na literatura. Portanto, nódulos menores que 10 mm podem ser abordados histologicamente pela biópsia de fragmento com segurança.<br>PURPOSE: to evaluate the diagnostic efficacy of core needle biopsy in suspicious solid breast masses (Bi-Rads&trade; 4 or 5) up to 10 mm. METHODS: this study was conducted on 83 women diagnosed with 90 suspicious solid lumps, all measuring up to 10 mm, identified by mammography (41), sonography (47) or palpation (two), who visited our clinic from September 2003 to January 2006. The lesions were biopsied with automatic device and 14 gauge needle (Bard, Corington, GA), all of them ultrasound guided. According to the pathological report, the biopsies were classified as true-positives, false-positives, true-negatives, and false-negatives. The sensitivity and specificity of ultrasound-guided core biopsy in breast masses up to 1 cm were calculated. RESULTS: the mean patient age was 52.5 years, and the mean diameter of the lesions was 7.3 mm, ranging from 3 to 10 mm. The results yielded by the pathologist showed 40 benign lesions (44.4%), 49 malignant lesions (54.4%) and one case (1.1%) of inconclusive material. This patient was submitted to ultrasound guided core needle biopsy once again, this time with conclusive results. There was agreement between histology and radiology in 89 cases. Sensitivity of ultrasound guided core biopsy for the diagnosis of breast cancer was 98.8 % and specificity 100%. CONCLUSIONS: the results obtained by ultrasound-guided core biopsy in suspicious breast lesions up to 10 mm are comparable to the best results of any kind of biopsy in the literature. Therefore, even solid lesions smaller or equal to 10 mm can be safely evaluated pathologically by core biopsy.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, H. S. A. D. C. J. E. (2007). Biópsia de fragmento em nódulos mamários suspeitos com até 10 mm Core biopsy in suspicious solid breast lesions up to 10 mm. https://doi.org/10.1590/S0100-72032007000600007

MLA

al, Hélio Sebastião Amâncio de Camargo Júnior et. "Biópsia de fragmento em nódulos mamários suspeitos com até 10 mm Core biopsy in suspicious solid breast lesions up to 10 mm." 2007. https://doi.org/10.1590/S0100-72032007000600007.

Chicago

al, Hélio Sebastião Amâncio de Camargo Júnior et. 2007. "Biópsia de fragmento em nódulos mamários suspeitos com até 10 mm Core biopsy in suspicious solid breast lesions up to 10 mm.". https://doi.org/10.1590/S0100-72032007000600007.

Harvard

al, H. S. A. D. C. J. E. 2007, Biópsia de fragmento em nódulos mamários suspeitos com até 10 mm Core biopsy in suspicious solid breast lesions up to 10 mm, Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, available at: https://doi.org/10.1590/S0100-72032007000600007 [Accessed 29 Jun. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Biópsia de fragmento em nódulos mamários suspeitos com até 10 mm Core biopsy in suspicious solid breast lesions up to 10 mm
Autor / colaboradores
Hélio Sebastião Amâncio de Camargo Júnior et al
Editorial
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
Año de publicación
2007
ISSN
0100-7203
ISSN
0100-7203
Idioma
eng

Materias

Explorá otros recursos relacionados a partir de estas materias.

Copiado