Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Avaliação de microcalcificações mamárias de acordo com as classificações do Breast Imaging Reporting and Data System (BI-RADS TM) e de Le Gal Evaluation of breast microcalcifications according to Breast Imaging Reporting and Data System (BI-RADS TM) and Le Gal's classifications

Lúcio Márcio Perri de Resende et al · Federação Brasileira das Sociedades de Ginecologia e Obstetrícia · 2008

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A FEBRASGO e o Novo Ano

Questa pubblicazione seriale contiene 195 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

OBJETIVO: avaliar a acurácia da mamografia para o diagnóstico de microcalcificações mamárias suspeitas, com as classificações do Breast Imaging Reporting and Data System (BI-RADS TM) e Le Gal em comparação com o resultado histopatológico utilizado como padrão-ouro. MÉTODOS: foram selecionados dos arquivos dos blocos cirúrgicos, 130 casos operados com mamografias contendo somente microcalcificações mamárias, inicialmente classificadas como suspeitas sem lesões detectáveis ao exame clínico. Estas foram reclassificadas por dois examinadores, utilizando as classificações de Le Gal e BI-RADS TM, obtendo-se diagnóstico de consenso. As biópsias foram revistas por dois patologistas e foi obtido diagnóstico de consenso. A leitura das mamografias e a revisão das lâminas foram feitas em duplo-cego. As análises estatísticas utilizadas neste estudo foram o teste do chi2, o modelo Fleiss quadrático para VPP e o programa Epi-Info 6.0. RESULTADOS: a correlação entre a análise histopatológica e mamográfica, usando BI-RADS TM e Le Gal, mostrou a mesma sensibilidade de 96,4%, especificidade de 55,9 e 30,3%, valor preditivo positivo (VPP) de 37,5% e 27,5% e acurácia de 64,6 e 44,6%, respectivamente. Quando discriminamos por categorias de BI-RADS TM, obtivemos VPPs: categoria 2, 0%; categoria 3, 1,8%; categoria 4, 31,6% e categoria 5, 60%. Os VPPs pela classificação de Le Gal foram: categoria 2, 3,1%; categoria 3, 18,1 %; categoria 4, 26,4%; categoria 5, 66,7% e não classificável, 5,2%. CONCLUSÕES: observou-se uma maior precisão com a classificação de BI-RADS TM, porém não se conseguiu reduzir a ambigüidade na avaliação das microcalcificações mamárias.<br>PURPOSE: the aim of this study is to evaluate the accuracy of mammography in the diagnosis of suspicious breast microcalcifications, using BI-RADS TM and Le Gal's classifications. METHODS: one hundred and thirty cases were selected with mammograms contain only microcalcifications of file and initially classified as suspicious (categories 4 and 5) without lesions clinical detectable and reclassified by two examiners, getting a consensus diagnosis. The biopsies were reviewed by two pathologists getting also a consensus diagnosis. Both, mammogram and histopathologic analysis were double blinded reviewed. Qui-square test, Fleiss-square statistic and EPI-INFO 6.0 were used in this study. RESULTS: the correlation between histopathological and mammographic analysis using BI-RADS TM and Le Gal classification showed the same sensitivity of 96.4%, specificity of 55.9 and 30.3%, positive predictive value (PPV) of 37.5 and 27.5%, and accuracy of 64.6 and 44.6% respectively. The PPV by BI-RADS TM categories was: category 2, 0%; category 3, 1.8%; category 4, 30.8%; and category 5, 60%. The PPV by Le Gal classification was: category 2, 3.1%; category 3, 18.1%; category 4, 26.4%;category 5, 66.7%, and non classified 5.2%. CONCLUSIONS: the results were better for the classification of BI-RADS&trade;, but it did not get to reduce the ambiguity in assessment of breast microcalcifications.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, L. M. P. D. R. E. (2008). Avaliação de microcalcificações mamárias de acordo com as classificações do Breast Imaging Reporting and Data System (BI-RADS TM) e de Le Gal Evaluation of breast microcalcifications according to Breast Imaging Reporting and Data System (BI-RADS TM) and Le Gal's classifications. https://doi.org/10.1590/S0100-72032008000200005

MLA

al, Lúcio Márcio Perri de Resende et. "Avaliação de microcalcificações mamárias de acordo com as classificações do Breast Imaging Reporting and Data System (BI-RADS TM) e de Le Gal Evaluation of breast microcalcifications according to Breast Imaging Reporting and Data System (BI-RADS TM) and Le Gal's classifications." 2008. https://doi.org/10.1590/S0100-72032008000200005.

Chicago

al, Lúcio Márcio Perri de Resende et. 2008. "Avaliação de microcalcificações mamárias de acordo com as classificações do Breast Imaging Reporting and Data System (BI-RADS TM) e de Le Gal Evaluation of breast microcalcifications according to Breast Imaging Reporting and Data System (BI-RADS TM) and Le Gal's classifications.". https://doi.org/10.1590/S0100-72032008000200005.

Harvard

al, L. M. P. D. R. E. 2008, Avaliação de microcalcificações mamárias de acordo com as classificações do Breast Imaging Reporting and Data System (BI-RADS TM) e de Le Gal Evaluation of breast microcalcifications according to Breast Imaging Reporting and Data System (BI-RADS TM) and Le Gal's classifications, Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, available at: https://doi.org/10.1590/S0100-72032008000200005 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Avaliação de microcalcificações mamárias de acordo com as classificações do Breast Imaging Reporting and Data System (BI-RADS TM) e de Le Gal Evaluation of breast microcalcifications according to Breast Imaging Reporting and Data System (BI-RADS TM) and Le Gal's classifications
Autore / collaboratori
Lúcio Márcio Perri de Resende et al
Editore
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
Anno di pubblicazione
2008
ISSN
0100-7203
ISSN
0100-7203
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato