Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Protection System Coordination On 20 kV Distribution Network In Makassar City

Firdaus Firdaus et al · Department of Electrical Engineering, Faculty of Engineering, Universitas Khairun · 2023

Testo completo ad accesso aperto
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Testo completo ad accesso aperto

Texto completo identificado como acceso abierto.
Apri testo

Riepilogo

Descripción general del contenido del recurso.

This study is a quantitative study that aims to a) describe the coordination of protection systems under abnormal conditions in the distribution network and b) to determine the selectiveity of protection systems in isolating equipment in abnormal conditions of distribution networks. Data setting existing rele protection system obtained in PT. PLN (Persero) UP2D Makassar, the data is then processed, simulated, and analyzed using the ETAP 19.0.1 program. The series analyzed in this study is the distribution network PLN ULP Karebosi Paotere refiner with a channel length of 8,234 km, where sktm channel 0.844 km and SUTM 7,390 km, consisting of 33 distribution substations. The results showed that the flow of short circuit disruption on Hatta buses was: 3-Phase by 3,887 kA, Line-to-Ground by 3,550 kA, Line-to-Line by 3,357 kA, and Line-to-Line-to-Ground by 3,831 kA. To achieve reliability and coordination of protection system equipment resetting rele on recloser Sabutung Set OCR 250 kA, TMS-TD OCR 0.08 s, moment OCR 3x, Sect. Paotere bridge OCR 200 kA, TMS-TD OCR 0.07 s, moment OCR Block, Sect. Hatta OCR 180 kA, TMS-TD OCR 0.05 s, moment OCR Block.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, F. F. E. (2023). Protection System Coordination On 20 kV Distribution Network In Makassar City. https://doi.org/10.33387/protk.v10i2.4204

MLA

al, Firdaus Firdaus et. "Protection System Coordination On 20 kV Distribution Network In Makassar City." 2023. https://doi.org/10.33387/protk.v10i2.4204.

Chicago

al, Firdaus Firdaus et. 2023. "Protection System Coordination On 20 kV Distribution Network In Makassar City.". https://doi.org/10.33387/protk.v10i2.4204.

Harvard

al, F. F. E. 2023, Protection System Coordination On 20 kV Distribution Network In Makassar City, Department of Electrical Engineering, Faculty of Engineering, Universitas Khairun, available at: https://doi.org/10.33387/protk.v10i2.4204 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Protection System Coordination On 20 kV Distribution Network In Makassar City
Autore / collaboratori
Firdaus Firdaus et al
Editore
Department of Electrical Engineering, Faculty of Engineering, Universitas Khairun
Anno di pubblicazione
2023
ISSN
2354-8924
ISSN
2354-8924
Lingua
Inglés
Copiato