Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Effect of storage temperature and time on measurement of serum symmetric dimethylarginine concentration using point‐of‐care and commercial laboratory analyzers in cats and dogs

Marleen Brans et al · Oxford University Press · 2023

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

Questa pubblicazione seriale contiene 149 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Abstract Background Stability of serum symmetric dimethylarginine (sSDMA) during short‐ and long‐term storage has not been assessed for the immunoassay of the Point‐of‐Care IDEXX Catalyst DX (POC) analyzer and the Enzyme Multiplied Immunoassay Technique of IDEXX commercial laboratory (CL). Also, the agreement between both analyzers is questioned. Objectives To determine (a) the effect of storage time and temperature on sSDMA measured by POC and CL; (b) the agreement between sSDMA measured by POC and CL; and (c) the imprecision of the POC. Animals Serum of cats (n = 17) and dogs (n = 18) with a range of SDMA concentrations (6 to >100 μg/dL). Methods Based on an equivalence trial with predefined equivalence range (−3.0 to +3.0 μg/dL) and using T0 as baseline, stability was evaluated after 24 hours at 22°C and 4°C (POC); after 7 days at 4°C (POC and CL) and after 10 and 24 months at −24°C and −80°C (CL). Bland‐Altman plots enabled method comparison. Imprecision of the POC was assessed by duplicate sSDMA measurements at T0. Results The POC analyzer produced equivalent sSDMA measurements if samples were stored for 24 hours at 4°C (95% confidence interval [CI]: −2.5‐2.0 μg/dL), but not when stored for 24 hours at room temperature (RT; 95% CI: −4.1 to 0.5 μg/dL) or after 7 days at 4°C (95% CI: −3.6‐1.0 μg/dL). The CL analyzer was less affected by preanalytical variation with clinically similar results obtained when samples were stored for 7 days at 4°C (95% CI: −2.2 to 2.4 μg/dL) and for at least 24 months at −24°C (95% CI: −1.7 to 2.9 μg/dL) and −80°C (95% CI: −1.5 to 3 μg/dL). A relevant mean difference of −2.3 μg/dL between both analyzers was found. Duplicate POC measurements were equivalent (95% CI: −2.6 to 2.0 μg/dL). Conclusions Delayed analysis may significantly change sSDMA depending on storage and measurement conditions. Interchangeable use of assays should be done with caution because analytical variation could be interpreted as clinically relevant change.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, M. B. E. (2023). Effect of storage temperature and time on measurement of serum symmetric dimethylarginine concentration using point‐of‐care and commercial laboratory analyzers in cats and dogs. https://doi.org/10.1111/jvim.16811

MLA

al, Marleen Brans et. "Effect of storage temperature and time on measurement of serum symmetric dimethylarginine concentration using point‐of‐care and commercial laboratory analyzers in cats and dogs." 2023. https://doi.org/10.1111/jvim.16811.

Chicago

al, Marleen Brans et. 2023. "Effect of storage temperature and time on measurement of serum symmetric dimethylarginine concentration using point‐of‐care and commercial laboratory analyzers in cats and dogs.". https://doi.org/10.1111/jvim.16811.

Harvard

al, M. B. E. 2023, Effect of storage temperature and time on measurement of serum symmetric dimethylarginine concentration using point‐of‐care and commercial laboratory analyzers in cats and dogs, Oxford University Press, available at: https://doi.org/10.1111/jvim.16811 [Accessed 9 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Effect of storage temperature and time on measurement of serum symmetric dimethylarginine concentration using point‐of‐care and commercial laboratory analyzers in cats and dogs
Autore / collaboratori
Marleen Brans et al
Editore
Oxford University Press
Anno di pubblicazione
2023
ISSN
0891-6640
ISSN
0891-6640
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato