Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Accuracy and Precision of Noninvasive Blood Pressure in Normo‐, Hyper‐, and Hypotensive Standing and Anesthetized Adult Horses

N. Heliczer et al · Oxford University Press · 2016

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

Questa pubblicazione seriale contiene 149 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Background Blood pressure is relevant to the diagnosis and management of many medical, cardiovascular and critical diseases. The accuracy of many commonly used noninvasive blood pressure (NIBP) monitors and the accuracy of NIBP measurements in hypo‐ and hypertensive standing horses has not been determined. Hypothesis/Objectives The objective of this study was to investigate the accuracy of an oscillometric BP monitor in standing horses before and during pharmacologically induced hyper‐ and hypotension and to compare results in standing and anesthetized horses. Animals Eight standing mares from a research herd (SG) and eight anesthetized horses from a hospital population (AG). Methods Prospective experimental and observational studies. Invasive blood pressure (IBP) and NIBP, corrected to heart level, were measured simultaneously. In the SG hyper‐ and hypotension were induced by administration of phenylephrine (3 μg/kg/min IV for 15 minutes) and acepromazine (0.05 mg/kg IV), respectively. In the AG NIBP and IBP were recorded during regular hospital procedures. Results There was a significant correlation between mean NIBP and IBP in standing (R = 0.88, P < .001) and anesthetized horses (R = 0.81, P < .001). The mean bias (lower, upper limit of agreement) was 16.4(−16.1, 48.9) mmHg for mean BP in the SG and 0.5(−22.3, 23.2) mmHg in the AG. The NIBP device was capable of identifying the increase and decrease in BP in all horses, but in the SG significant correlation between NIBP and IBP was only detected for the normotensive phase. Conclusion and Clinical Importance While the evaluated oscillometric BP device allowed estimation of BP and adequately differentiated marked trends, the accuracy and precision were low in standing horses.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, N. H. E. (2016). Accuracy and Precision of Noninvasive Blood Pressure in Normo‐, Hyper‐, and Hypotensive Standing and Anesthetized Adult Horses. https://doi.org/10.1111/jvim.13928

MLA

al, N. Heliczer et. "Accuracy and Precision of Noninvasive Blood Pressure in Normo‐, Hyper‐, and Hypotensive Standing and Anesthetized Adult Horses." 2016. https://doi.org/10.1111/jvim.13928.

Chicago

al, N. Heliczer et. 2016. "Accuracy and Precision of Noninvasive Blood Pressure in Normo‐, Hyper‐, and Hypotensive Standing and Anesthetized Adult Horses.". https://doi.org/10.1111/jvim.13928.

Harvard

al, N. H. E. 2016, Accuracy and Precision of Noninvasive Blood Pressure in Normo‐, Hyper‐, and Hypotensive Standing and Anesthetized Adult Horses, Oxford University Press, available at: https://doi.org/10.1111/jvim.13928 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Accuracy and Precision of Noninvasive Blood Pressure in Normo‐, Hyper‐, and Hypotensive Standing and Anesthetized Adult Horses
Autore / collaboratori
N. Heliczer et al
Editore
Oxford University Press
Anno di pubblicazione
2016
ISSN
0891-6640
ISSN
0891-6640
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato