← Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo

Correlação entre medidas ultra-sonográficas do coração e o deficit de hemoglobina em fetos de gestantes aloimunizadas Correlation between echographic cardiac measurements and hemoglobin deficit in fetus of red cell alloimmunized pregnancies

Marília Zicker Hanan et al · Federação Brasileira das Sociedades de Ginecologia e Obstetrícia · 2008

Material complementario disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.
Publicación seriada

A FEBRASGO e o Novo Ano

Esta publicación seriada contiene 195 contenidos relacionados.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

Acceso principal

Material complementario disponible

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Abrir material

Resumen

Descripción general del contenido del recurso.

OBJETIVO: verificar a correlação entre as medidas ultra-sonográficas do coração fetal e o deficit de hemoglobina em fetos de gestantes aloimunizadas. MÉTODOS: estudo transversal, no qual foram incluídos 60 fetos de 56 mulheres aloimunizadas, com idade gestacional entre 21 e 35 semanas. Foram realizados 139 procedimentos. Antes da cordocentese para a coleta de sangue fetal, as medidas cardíacas e o comprimento do fêmur (CF) foram avaliados pela ultra-sonografia. O diâmetro biventricular externo (DBVE) foi obtido no final da diástole, com o cursor modo-M perpendicular ao septo interventricular, nas válvulas atrioventriculares, medindo-se a distância entre as partes externas dos epicárdios. A medida do diâmetro atrioventricular (DAV) foi obtida posicionando-se o mesmo cursor ao longo do septo interventricular, avaliando-se a distância entre a base e o ápice do coração. O CF foi determinado do trocanter maior à metáfise distal. Foi calculada a circunferência cardíaca (CC). Para ajustar as medidas cardíacas à idade gestacional, dividiu-se cada uma dessas medidas pela medida do CF. A concentração de hemoglobina foi determinada por espectrofotometria no sistema Hemocue®. O deficit de hemoglobina foi calculado baseado na curva de normalidade de Nicolaides. RESULTADOS: observaram-se correlações diretas e significativas entre as medidas cardíacas avaliadas e o deficit de hemoglobina. Para a predição das anemias moderada e grave, a sensibilidade e a especificidade encontradas foram, respectivamente, de 71,7 e 66,3% para a razão DBVE e CF; 65,8 e 62,4% para a DAV e CF e 73,7 e 60,4% para a CC e CF. CONCLUSÕES: nos fetos de gestantes aloimunizadas, as medidas cardíacas ultra-sonográficas avaliadas correlacionam-se diretamente com o deficit de hemoglobina.<br>PURPOSE: to verify the correlation between ultrasonography heart measures and hemoglobin deficit in fetuses of alloimmunized pregnant women. METHODS: a transversal study, including 60 fetuses, with 21 to 35 weeks of gestational age, from 56 isoimmunized pregnant women. A number of 139 procedures were performed. Before cordocentesis for the collection of fetal blood, cardiac measures and femur length (FL) were assessed by ultrasonography. The external biventricular diameter (EBVD) was obtained by measuring the distance between the epicardic external parts at the end of the diastole, with the M-mode cursor perpendicular to the interventricular septum, in the atrioventricular valves. The measure of the atrioventricular diameter (AVD) was obtained by positioning the same cursor along the interventricular septum, evaluating the distance between the heart basis and apex. The FL was determined from the trochanter major to the distal metaphysis. The cardiac circumference (CC) was also calculated. To adjust the cardiac measure to the gestational age, each of these measures were divided by the FL measure. Hemoglobin concentration has been determined by spectrophotometry with the Hemocue® system. Hemoglobin deficit calculation was based in the Nicolaides's normality curve. RESULTS: direct and significant correlations were observed between the cardiac measures evaluated and the hemoglobin deficit. To predict moderate and severe anemia, the sensitivity and specificity found were 71.7 and 66.3% for EBVD and FL, 65.8 and 62.4% for AVD and FL, and 73.7 and 60.4% for CC and FL, respectively. CONCLUSIONS: ultrasonography cardiac measures assessed from fetuses of isoimmunized pregnant women correlate directly with hemoglobin deficit.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, M. Z. H. E. (2008). Correlação entre medidas ultra-sonográficas do coração e o deficit de hemoglobina em fetos de gestantes aloimunizadas Correlation between echographic cardiac measurements and hemoglobin deficit in fetus of red cell alloimmunized pregnancies. https://doi.org/10.1590/S0100-72032008000700004

MLA

al, Marília Zicker Hanan et. "Correlação entre medidas ultra-sonográficas do coração e o deficit de hemoglobina em fetos de gestantes aloimunizadas Correlation between echographic cardiac measurements and hemoglobin deficit in fetus of red cell alloimmunized pregnancies." 2008. https://doi.org/10.1590/S0100-72032008000700004.

Chicago

al, Marília Zicker Hanan et. 2008. "Correlação entre medidas ultra-sonográficas do coração e o deficit de hemoglobina em fetos de gestantes aloimunizadas Correlation between echographic cardiac measurements and hemoglobin deficit in fetus of red cell alloimmunized pregnancies.". https://doi.org/10.1590/S0100-72032008000700004.

Harvard

al, M. Z. H. E. 2008, Correlação entre medidas ultra-sonográficas do coração e o deficit de hemoglobina em fetos de gestantes aloimunizadas Correlation between echographic cardiac measurements and hemoglobin deficit in fetus of red cell alloimmunized pregnancies, Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, available at: https://doi.org/10.1590/S0100-72032008000700004 [Accessed 30 Jun. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Correlação entre medidas ultra-sonográficas do coração e o deficit de hemoglobina em fetos de gestantes aloimunizadas Correlation between echographic cardiac measurements and hemoglobin deficit in fetus of red cell alloimmunized pregnancies
Autor / colaboradores
Marília Zicker Hanan et al
Editorial
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
Año de publicación
2008
ISSN
0100-7203
ISSN
0100-7203
Idioma
eng

Materias

Explorá otros recursos relacionados a partir de estas materias.

Copiado