EVALUATION SUBSTATION PROTECTION SYSTEM FROM LIGHTNING STRIKES AT 150KV JATIGEDE SUBSTATION

Taryo Taryo et al · Department of Electrical Engineering, Faculty of Engineering, Universitas Khairun · 2025

Testo completo ad accesso aperto
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Testo completo ad accesso aperto

Texto completo identificado como acceso abierto.
Apri testo

Riepilogo

Descripción general del contenido del recurso.

Grounding serves a crucial role in the field lightning protection, electric power, and electric power communications networks. The grounding system's purpose is to guide the flow of electrical charges to the ground mass as rapidly as feasible. The goal of this study is to analyze the grounding system utilized to ensure the continuity of electrical energy production and delivery. In this study, quantitative methods are used to calculate lightning parameters, substation protection by earthing wires and protection towers, earthing system, mesh voltages, touch voltages and step voltages. According to IEEE 80-2013 (latest revision) standards, an ideal earthing application should have a resistance value of 1Ω. The results of the analysis and calculation of the grounding system using the grid grounding type obtained a value of 0.28276 Ω (1Ω), and mesh voltage 0,851314 kV. The protection system which consists of a 103.47288 M ground wire and a 55.27325 M protection tower, is capable of protecting the substation from lightning strikes with a peak current of 51.32913 kA. The touch voltage for humans weighing 50kg and 70kg is 133.39304 V and 180.54060 V, and the step voltage results in 185.5770 V and 251.1690 V. When the grounding current at touch and step voltages is considered, the values become 442.87730 kV and 616.17712 kV. Both exceed the allowed levels of 626 and 2,216 V.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, T. T. E. (2025). EVALUATION SUBSTATION PROTECTION SYSTEM FROM LIGHTNING STRIKES AT 150KV JATIGEDE SUBSTATION. https://doi.org/10.33387/protk.v12i1.8319

MLA

al, Taryo Taryo et. "EVALUATION SUBSTATION PROTECTION SYSTEM FROM LIGHTNING STRIKES AT 150KV JATIGEDE SUBSTATION." 2025. https://doi.org/10.33387/protk.v12i1.8319.

Chicago

al, Taryo Taryo et. 2025. "EVALUATION SUBSTATION PROTECTION SYSTEM FROM LIGHTNING STRIKES AT 150KV JATIGEDE SUBSTATION.". https://doi.org/10.33387/protk.v12i1.8319.

Harvard

al, T. T. E. 2025, EVALUATION SUBSTATION PROTECTION SYSTEM FROM LIGHTNING STRIKES AT 150KV JATIGEDE SUBSTATION, Department of Electrical Engineering, Faculty of Engineering, Universitas Khairun, available at: https://doi.org/10.33387/protk.v12i1.8319 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
EVALUATION SUBSTATION PROTECTION SYSTEM FROM LIGHTNING STRIKES AT 150KV JATIGEDE SUBSTATION
Autore / collaboratori
Taryo Taryo et al
Editore
Department of Electrical Engineering, Faculty of Engineering, Universitas Khairun
Anno di pubblicazione
2025
ISSN
2354-8924
ISSN
2354-8924
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato