A Robotic System with Robust Remote Center of Motion Constraint for Endometrial Regeneration Surgery

Jianhua Li et al · KeAi Communications Co., Ltd · 2022

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Abstract Surgical robots have been widely used in different procedures to improve and facilitate the surgery. However, there is no robot designed for endometrial regeneration surgery, which is a new therapy for restoring fertility in women using stem cells. Endometrial regeneration surgery requires processing of the endometrium and transplantation of stem cells with minimal trauma to the uterus. In this paper, we introduce a surgical robotic system that consists of a dexterous hysteroscope, supporting arm, and additional novel instruments to facilitate the operation and decrease trauma to the uterus. Remote center of motion (RCM) constraint is required to protect the cervix of the uterus. First, the supporting arm and hysteroscope are controlled separately in kinematics to ensure that the RCM constraint and hysteroscope’s shape and posture are predictable. Then, a task-decoupled method is used to improve the robustness of the RCM constraint. Experiments confirm that the proposed method is more robust and achieves higher RCM accuracy. In addition, the master-slave control of a robot with RCM constraint is also verified. This study proposes the realization of a robot with robust RCM control for endometrial regeneration surgery.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, J. L. E. (2022). A Robotic System with Robust Remote Center of Motion Constraint for Endometrial Regeneration Surgery. https://doi.org/10.1186/s10033-022-00731-2

MLA

al, Jianhua Li et. "A Robotic System with Robust Remote Center of Motion Constraint for Endometrial Regeneration Surgery." 2022. https://doi.org/10.1186/s10033-022-00731-2.

Chicago

al, Jianhua Li et. 2022. "A Robotic System with Robust Remote Center of Motion Constraint for Endometrial Regeneration Surgery.". https://doi.org/10.1186/s10033-022-00731-2.

Harvard

al, J. L. E. 2022, A Robotic System with Robust Remote Center of Motion Constraint for Endometrial Regeneration Surgery, KeAi Communications Co, Ltd, available at: https://doi.org/10.1186/s10033-022-00731-2 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
A Robotic System with Robust Remote Center of Motion Constraint for Endometrial Regeneration Surgery
Autore / collaboratori
Jianhua Li et al
Editore
KeAi Communications Co., Ltd
Anno di pubblicazione
2022
ISSN
1000-9345
ISSN
1000-9345
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato