Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Acurácia da estimativa ultrassonográfica do peso fetal e influência de fatores maternos e fetais Ultrasonographic accuracy of fetal weight estimation and influence of maternal and fetal factors

Aline Giroto Ricci et al · Federação Brasileira das Sociedades de Ginecologia e Obstetrícia · 2011

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A FEBRASGO e o Novo Ano

Questa pubblicazione seriale contiene 195 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

OBJETIVO: Avaliar a eficácia da estimativa ultrassonográfica na predição do peso fetal e analisar fatores maternos e/ou fetais que interferem no resultado. MÉTODOS: Estudo prospectivo e transversal, que incluiu 106 pacientes, nas quais foram realizadas 212 avaliações pela ultrassonografia, por 2 observadores, no máximo 24 h antes do parto. Foram mensurados os seguintes parâmetros: diâmetro biparietal (DBP), circunferência cefálica (CC), circunferência abdominal (CA) e comprimento do fêmur (CF).O peso fetal foi estimado utilizando-se a fórmula de Hadlock 4 parâmetros, e os resultados foram comparados com o peso no nascimento. Os fatores maternos avaliados foram peso materno, índice de massa corpórea (IMC) e distância entre a pele e o útero na ultrassonografia; e os fatores fetais: apresentação, posição, localização e espessura placentária, peso fetal e índice de líquido amniótico (ILA). RESULTADOS: Foi observada boa correlação entre o peso estimado e o peso no nascimento (R=0,97). Em 79,2% dos casos, a variação do peso fetal estimado, em relação ao peso no nascimento, foi de até 10% e, em 92,4% dos casos, de até 15%. O único fator materno que apresentou correlação positiva com o erro percentual na estimativa do peso fetal foi a distância entre a pele e o útero (R³0,56). A avaliação do peso fetal mostrou correlação negativa com o erro percentual (R=-0,36; p<0,001), com tendência significante em superestimar o peso no grupo abaixo de 1000 g (p<0,05). O ILA mostrou baixa relação negativa com o erro percentual (R=-0,21; p<0,001), sem diferença nos erros percentuais entre os diferentes grupos de ILA (p=0,516). CONCLUSÕES: A estimativa ultrassonográfica do peso fetal apresenta boa acurácia. O erro na estimativa do peso fetal é diretamente proporcional à distância entre a pele e o útero materno e inversamente proporcional ao peso fetal. O volume de líquido amniótico não interferiu significantemente na predição do peso fetal.<br>PURPOSE: To determine the accuracy of ultrasound in fetal weight estimation and to evaluate maternal and/or fetal factors that could interfere in the result. METHODS: This was a transverse prospective study, involving 106 patients, with 212 fetal weight evaluations, by two observers, within 24 h to delivery. The following parameters were measured: biparietal diameter, head circumference, abdominal circumference, and femoral length. Fetal weight was estimated using the Hadlock formula and the results were compared to birth weight. The maternal factors examined were: weight, BMI, and skin to uterus distance measured by ultrasound, and the fetal factors were: presentation, position, placental localization and thickness, fetal weight, and amniotic fluid index (AFI). RESULTS: There was good correlation between estimated fetal weight and birth weight (R=0.97). In 79.2% and in 92.4% of cases the estimated fetal weight was within 10% and 15% of birth weight, respectively. The only maternal factor that presented a positive correlation with percent error in the estimate of fetal weight was the skin to uterus distance (R³0.56). Fetal weight showed negative correlation with percent error (R>-0.36; p<0.001), with a significant tendency to overestimate fetal weight in the group of very low weight - <1000 g (p<0.05). The AFI showed a low negative correlation with percent error (R=-0.21; p<0.001) with no difference between AFI groups (p=0.516). CONCLUSION: Ultrasound presented good accuracy in the estimation of fetal weight. The error of weight estimate was directly proportional to the skin to uterus distance and inversely proportional to fetal weight. AFI did not interfere significantly in the ultrasound prediction of fetal weight.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, A. G. R. E. (2011). Acurácia da estimativa ultrassonográfica do peso fetal e influência de fatores maternos e fetais Ultrasonographic accuracy of fetal weight estimation and influence of maternal and fetal factors. https://doi.org/10.1590/S0100-72032011000900004

MLA

al, Aline Giroto Ricci et. "Acurácia da estimativa ultrassonográfica do peso fetal e influência de fatores maternos e fetais Ultrasonographic accuracy of fetal weight estimation and influence of maternal and fetal factors." 2011. https://doi.org/10.1590/S0100-72032011000900004.

Chicago

al, Aline Giroto Ricci et. 2011. "Acurácia da estimativa ultrassonográfica do peso fetal e influência de fatores maternos e fetais Ultrasonographic accuracy of fetal weight estimation and influence of maternal and fetal factors.". https://doi.org/10.1590/S0100-72032011000900004.

Harvard

al, A. G. R. E. 2011, Acurácia da estimativa ultrassonográfica do peso fetal e influência de fatores maternos e fetais Ultrasonographic accuracy of fetal weight estimation and influence of maternal and fetal factors, Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, available at: https://doi.org/10.1590/S0100-72032011000900004 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Acurácia da estimativa ultrassonográfica do peso fetal e influência de fatores maternos e fetais Ultrasonographic accuracy of fetal weight estimation and influence of maternal and fetal factors
Autore / collaboratori
Aline Giroto Ricci et al
Editore
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
Anno di pubblicazione
2011
ISSN
0100-7203
ISSN
0100-7203
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato