Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations

Francesca Del Baldo et al · Oxford University Press · 2021

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

Questa pubblicazione seriale contiene 149 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Abstract Background The FreeStyle Libre (Abbott Laboratories) is a flash glucose monitoring system (FGMS) that measures interstitial glucose concentration (IG). The system is factory‐calibrated, easy to use, inexpensive, and could be useful for monitoring diabetic cats. Objectives To evaluate the analytical and clinical accuracy of the FGMS in cats and establish the lag‐time between IG and blood glucose concentration (BG). Animals Twenty client‐owned diabetic cats and 7 purpose‐bred healthy cats. Methods Prospective study. Blood glucose concentration was measured using a portable glucose meter validated for use in cats that served as a reference method for IG, as measured by FGMS. In diabetic cats, data were collected for sensor wearing time with different methods of application and accuracy across glycemic ranges. Accuracy was determined by fulfillment of ISO15197:2013 criteria. In healthy cats, lag‐time between IG and BG was established after IV administration of exogenous glucose. Results Good agreement between IG and BG was obtained (r = .93). Analytical accuracy was not achieved, whereas clinical accuracy was demonstrated with 100% of the results in zones A + B of the Parkes consensus error grid analysis. In the immediate 30 minutes after an IV bolus of glucose, when BG was increasing rapidly (approximately 2%/min), IG increased slowly, resulting in a difference of as much as 579 mg/dL, and no positive correlation between BG and IG was found. Conclusions and Clinical Importance The FGMS did not fulfill ISO requirements but is sufficiently accurate for glucose monitoring in cats, while considering the lag between IG and BG during periods of rapid changes in BG.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, F. D. B. E. (2021). Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations. https://doi.org/10.1111/jvim.16122

MLA

al, Francesca Del Baldo et. "Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations." 2021. https://doi.org/10.1111/jvim.16122.

Chicago

al, Francesca Del Baldo et. 2021. "Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations.". https://doi.org/10.1111/jvim.16122.

Harvard

al, F. D. B. E. 2021, Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations, Oxford University Press, available at: https://doi.org/10.1111/jvim.16122 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations
Autore / collaboratori
Francesca Del Baldo et al
Editore
Oxford University Press
Anno di pubblicazione
2021
ISSN
0891-6640
ISSN
0891-6640
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato