← Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo

Effectiveness of clear aligner therapy in rotational tooth movement

Alaçam Aylin et al · Balkan Stomatological Society · 2024

Acceso abierto al texto completo
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

Acceso principal

Acceso abierto al texto completo

Texto completo identificado como acceso abierto.
Abrir texto

Resumen

Descripción general del contenido del recurso.

Background/Aim: The present study investigates the effectiveness of Invisalign (Align Technology, San Jose, Calif) in rotational tooth movement. The aim of this research is to assess the accuracy of the predicted rotational movements in the digital treatment plan (Clincheck, Align Technology, San Jose, CA) compared to the actual achieved results following treatment completion. Material and Methods: A retrospective analysis was conducted on a cohort of orthodontic patients who underwent clear aligner therapy for rotational tooth movements. Digital treatment plans and 3D models were used to predict the anticipated degree of rotation for each tooth. Post treatment, the achieved, rotational movements were measured in the same way and assessed quantitively. Results: Preliminary findings revealed a significant correlation between the predicted rotational movements and the actual outcomes. The variations were observed among different tooth types and degree of rotation, which were influenced by the complexity of the rotations and the type of teeth involved. Teeth with mild to moderate rotations demonstrated higher accuracy rates in alignment with the digital treatment plan, while more complex rotations exhibited slight discrepancies. The most accomplished tooth movement was found with 80 % accuracy in lower central incisors, 74.29 % accuracy in lower laterals, 71.43 % accuracy in upper central incisors and lower second premolars whereas the least accuracy was found with 28 % in lower canines. Conclusions: These results reveals the potential of Invisalign orthodontic treatment to accurately predict and achieve rotational movements. The study emphazises the importance of precise treatment planning and patient selection for optimal outcomes. Further research is warranted to explore factors contributing to the variations observed and to refine treatment protocols to enhance the accuracy of rotational tooth movements with Invisalign.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, A. A. E. (2024). Effectiveness of clear aligner therapy in rotational tooth movement. https://doi.org/10.5937/bjdm2403208A

MLA

al, Alaçam Aylin et. "Effectiveness of clear aligner therapy in rotational tooth movement." 2024. https://doi.org/10.5937/bjdm2403208A.

Chicago

al, Alaçam Aylin et. 2024. "Effectiveness of clear aligner therapy in rotational tooth movement.". https://doi.org/10.5937/bjdm2403208A.

Harvard

al, A. A. E. 2024, Effectiveness of clear aligner therapy in rotational tooth movement, Balkan Stomatological Society, available at: https://doi.org/10.5937/bjdm2403208A [Accessed 1 Jul. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Effectiveness of clear aligner therapy in rotational tooth movement
Autor / colaboradores
Alaçam Aylin et al
Editorial
Balkan Stomatological Society
Año de publicación
2024
ISSN
2335-0245
ISSN
2335-0245
Idioma
eng

Materias

Explorá otros recursos relacionados a partir de estas materias.

Copiado