Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Detecção e exérese de lesões mamárias não palpáveis orientadas por cirurgia radioguiada com injeção de ar para controle radiológico Detection and excision of non-palpable breast lesions by radioguided surgery and air injection for radiological control

Rafael Henrique Szymanski Machado et al · Federação Brasileira das Sociedades de Ginecologia e Obstetrícia · 2005

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A FEBRASGO e o Novo Ano

Questa pubblicazione seriale contiene 195 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

OBJETIVO: avaliar a eficiência da localização e exérese por cirurgia radioguiada de lesões ocultas mamárias utilizando radiofármaco injetado diretamente no interior das lesões ou até dois centímetros destas com posterior injeção de ar como controle radiológico. MÉTODOS: vinte e nove pacientes com 32 lesões mamárias ocultas, detectadas por mamografia ou ultra-sonografia, classificadas como Bi-Rads® 3, 4 e 5 foram incluídas neste estudo observacional com resultados expressos em percentagens. O radiofármaco utilizado foi o macroagregado de albumina marcado com tecnécio-99m (99mTc-MAA) injetado por orientação mamográfica ou guiado por ultra-sonografia. A injeção do radiofármaco foi seguida pela imediata administração de ar, através da agulha da estereotaxia, visando o controle radiológico da injeção do radiofármaco. A biopsia excisional foi feita com o auxílio do aparelho portátil gamma-probe (detector de radiação gama) e a remoção completa das lesões foi verificada pela radiografia das peças cirúrgicas ou por exame por congelação intra-operatório. RESULTADOS: câncer de mama foi encontrado em 10% (1/10) das lesões BI-RADS® 3, em 31,5% (6/19) das BI-RADS® 4 e em 66,6% (2/3) das BI-RADS® 5. As 29 pacientes corresponderam a 32 espécimes, cirúrgicos. O radiofármaco foi corretamente posicionado em 96,8% (31/32) dos espécimes permitindo remoção de 96,8% das lesões mamárias não palpáveis estudadas. A completa remoção da lesão foi demonstrada pela radiografia das peças em 23 casos (71,8%), pelo estudo intra-operatório por congelação em 21,8% (7/32) e por ambos os métodos em 6,2% (2/32). CONCLUSÃO: a cirurgia radioguiada é importante instrumento na remoção de lesões mamárias não palpáveis, tratando-se de método simples, rápido e exeqüível que pode ser implementado na rotina clínica dessas pacientes.<br>PURPOSE: to asses the efficiency of the radioguided localization and removal of occult breast lesions using radiopharmaceuticals injected directly into the lesions or close to them with posterior air injection as a radiological control. METHODS: twenty-nine consecutive patients with thirty-two occult breast lesions detected mammographically or by ultrasound, and categorized 3, 4 and 5 BI-RADS®, were included in this observational study with results expressed in percentages. The radiopharmaceutical used was human serum albumin labeled with 99mTc-HSA injected inside or close to the lesion using mammographic or ultrasonographic guidance. The injection of the radiopharmaceutical was followed immediately by air injection through the needle used for stereotaxis as a radiological control of the radiopharmaceutical placement. The excision biopsy was carried out with the aid of a hand-held gamma-detecting probe and the entire removal of the lesion was verified by X-ray of the surgical specimens or by intraoperative frozen section examination. RESULTS: breast cancer was found in 10.0% (1/10) of the 3 BI-RADS® lesions, in 31.5% (6/19) of the 4 BI-RADS® and in 66.6% (2/3) of the 5 BI-RADS®. The radiotracer was correctly positioned in 96.8% of the specimens (31/32) allowing the removal of also 96.8% of the studied non-palpable breast lesions. To show the entire removal, X-ray was used in 23 cases (71.8%), intraoperative frozen section study in 21.8% (7/32) and both methods in 6.2% (2/32). CONCLUSIONS: radioguided surgery showed to be an important tool in the removal of non-palpable breast lesions, as a simple, fast and feasible method that can be implemented in the clinical routine of these patients.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, R. H. S. M. E. (2005). Detecção e exérese de lesões mamárias não palpáveis orientadas por cirurgia radioguiada com injeção de ar para controle radiológico Detection and excision of non-palpable breast lesions by radioguided surgery and air injection for radiological control. https://doi.org/10.1590/S0100-72032005001100003

MLA

al, Rafael Henrique Szymanski Machado et. "Detecção e exérese de lesões mamárias não palpáveis orientadas por cirurgia radioguiada com injeção de ar para controle radiológico Detection and excision of non-palpable breast lesions by radioguided surgery and air injection for radiological control." 2005. https://doi.org/10.1590/S0100-72032005001100003.

Chicago

al, Rafael Henrique Szymanski Machado et. 2005. "Detecção e exérese de lesões mamárias não palpáveis orientadas por cirurgia radioguiada com injeção de ar para controle radiológico Detection and excision of non-palpable breast lesions by radioguided surgery and air injection for radiological control.". https://doi.org/10.1590/S0100-72032005001100003.

Harvard

al, R. H. S. M. E. 2005, Detecção e exérese de lesões mamárias não palpáveis orientadas por cirurgia radioguiada com injeção de ar para controle radiológico Detection and excision of non-palpable breast lesions by radioguided surgery and air injection for radiological control, Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, available at: https://doi.org/10.1590/S0100-72032005001100003 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Detecção e exérese de lesões mamárias não palpáveis orientadas por cirurgia radioguiada com injeção de ar para controle radiológico Detection and excision of non-palpable breast lesions by radioguided surgery and air injection for radiological control
Autore / collaboratori
Rafael Henrique Szymanski Machado et al
Editore
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
Anno di pubblicazione
2005
ISSN
0100-7203
ISSN
0100-7203
Lingua
Inglés
Copiato