Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Evaluation of a flash glucose monitoring system in nondiabetic dogs with rapidly changing blood glucose concentrations

Leigh A. Howard et al · Oxford University Press · 2021

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

Questa pubblicazione seriale contiene 149 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Abstract Background A flash glucose monitoring system (FGMS; FreeStyle Libre) is useful for monitoring hypoglycemic dogs with diabetes. Objective To assess the utility of this FGMS in dogs with induced hypoglycemia and rapid fluctuations in blood glucose (BG) concentrations. Animals Twenty‐four apparently healthy research (n = 10) and teaching (n = 14) dogs. Methods Prospective, observational study performed in tandem with a teaching laboratory. Regular insulin was administered to dogs and resulting hypoglycemia was corrected. Before insulin administration and every 10 minutes over a 90‐minute period, serial measurements of interstitial glucose (IG) with FGMS and BG with a portable blood glucose meter (PBGM) and clinical chemistry analyzer concentrations were made. Portable blood glucose meter and FGMS readings were compared to that of the clinical chemistry analyzer. Analytical and clinical accuracy were assessed using ISO 15197:2013 criteria, including Parkes error grid analysis. Results The proportions of readings in the low BG range (BG <100 mg/dL) for which the test method measurement was within ±15 mg/dL of the reference BG for the PBGM and FGMS were 81.7% (161/197) and 39.1% (72/184), respectively. The proportions of readings for the PBGM and FGMS, which were not likely to affect clinical outcome according to Parkes error grid analysis, were 97.9% (233/238) and 80.1% (177/221), respectively. Conclusions and Clinical Importance In this model, there was limited agreement between the FGMS and reference standard BG measurements. The FGMS (measuring IG concentrations) was compared to peripheral BG concentrations, not brain‐tissue glucose concentrations, and failed to reliably detect hypoglycemia.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, L. A. H. E. (2021). Evaluation of a flash glucose monitoring system in nondiabetic dogs with rapidly changing blood glucose concentrations. https://doi.org/10.1111/jvim.16273

MLA

al, Leigh A. Howard et. "Evaluation of a flash glucose monitoring system in nondiabetic dogs with rapidly changing blood glucose concentrations." 2021. https://doi.org/10.1111/jvim.16273.

Chicago

al, Leigh A. Howard et. 2021. "Evaluation of a flash glucose monitoring system in nondiabetic dogs with rapidly changing blood glucose concentrations.". https://doi.org/10.1111/jvim.16273.

Harvard

al, L. A. H. E. 2021, Evaluation of a flash glucose monitoring system in nondiabetic dogs with rapidly changing blood glucose concentrations, Oxford University Press, available at: https://doi.org/10.1111/jvim.16273 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Evaluation of a flash glucose monitoring system in nondiabetic dogs with rapidly changing blood glucose concentrations
Autore / collaboratori
Leigh A. Howard et al
Editore
Oxford University Press
Anno di pubblicazione
2021
ISSN
0891-6640
ISSN
0891-6640
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato