Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Document

Automatic detection of reverse‑triggering related asynchronies during mechanical ventilation in ARDS patients using flow and pressure signals

Rodríguez, Pablo Oscar et al · RI ITBA · 2020

Testo completo ad accesso aperto
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

RI ITBA RI ITBA OAI-PMH
Entrar por RI ITBA
Accesso principale

Testo completo ad accesso aperto

Texto completo identificado como acceso abierto.
Apri testo

Riepilogo

Descripción general del contenido del recurso.

"Asynchrony due to reverse-triggering (RT) may appear in ARDS patients. The objective of this study is to validate an algo-rithm developed to detect these alterations in patient–ventilator interaction. We developed an algorithm that uses flow and airway pressure signals to classify breaths as normal, RT with or without breath stacking (BS) and patient initiated double-triggering (DT). The diagnostic performance of the algorithm was validated using two datasets of breaths, that are classified as stated above. The first dataset classification was based on visual inspection of esophageal pressure (Pes) signal from 699 breaths recorded from 11 ARDS patients. The other classification was obtained by vote of a group of 7 experts (2 physicians and 5 respiratory therapists, who were trained in ICU), who evaluated 1881 breaths gathered from recordings from 99 sub-jects. Experts used airway pressure and flow signals for breaths classification. The RT with or without BS represented 19% and 37% of breaths in Pes dataset while their frequency in the expert’s dataset were 3% and 12%, respectively. The DT was very infrequent in both datasets. Algorithm classification accuracy was 0.92 (95% CI 0.89–0.94, P < 0.001) and 0.96 (95% CI 0.95–0.97, P < 0.001), in comparison with Pes and experts’ opinion. Kappa statistics were 0.86 and 0.84, respectively. The algorithm precision, sensitivity and specificity for individual asynchronies were excellent. The algorithm yields an excellent accuracy for detecting clinically relevant asynchronies related to RT."

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

Rodríguez, P. O. E. A. (2020). Automatic detection of reverse‑triggering related asynchronies during mechanical ventilation in ARDS patients using flow and pressure signals. RI ITBA. http://ri.itba.edu.ar/handle/20.500.14769/1916

MLA

Rodríguez, Pablo Oscar et al. Automatic detection of reverse‑triggering related asynchronies during mechanical ventilation in ARDS patients using flow and pressure signals. RI ITBA, 2020. http://ri.itba.edu.ar/handle/20.500.14769/1916.

Chicago

Rodríguez, Pablo Oscar et al. 2020. Automatic detection of reverse‑triggering related asynchronies during mechanical ventilation in ARDS patients using flow and pressure signals. RI ITBA. http://ri.itba.edu.ar/handle/20.500.14769/1916.

Harvard

Rodríguez, P. O. E. A. 2020, Automatic detection of reverse‑triggering related asynchronies during mechanical ventilation in ARDS patients using flow and pressure signals, RI ITBA, available at: http://ri.itba.edu.ar/handle/20.500.14769/1916 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Automatic detection of reverse‑triggering related asynchronies during mechanical ventilation in ARDS patients using flow and pressure signals
Autore / collaboratori
Rodríguez, Pablo Oscar et al
Editore
RI ITBA
Anno di pubblicazione
2020
ISSN
1387-1307
ISSN
1387-1307
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato