Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Evaluation of a continuous glucose monitoring system in neonatal foals

David Wong et al · Oxford University Press · 2021

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

Questa pubblicazione seriale contiene 149 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Abstract Background Monitoring blood glucose concentrations is common in critically ill neonatal foals, especially septic foals and those receiving naso‐esophageal feedings or IV parenteral nutrition. Glucose typically is measured using a point‐of‐care (POC) glucometer but requires repeated restraint and blood collections, which may cause irritation at venipuncture sites and increased demands on nursing staff. Continuous glucose monitoring systems (CGMS) may provide an accurate alternative for monitoring blood glucose concentration. Objectives To determine the correlation and accuracy of a CGMS to monitor neonatal foals' blood glucose concentrations as compared to a POC glucometer and laboratory chemistry analysis (CHEM). Animals Samples from 4 healthy and 4 ill neonatal foals. Methods A CGMS was placed on each foal, and glucose measurements acquired from this device were compared to simultaneous measurements of blood glucose concentration using a POC glucometer and CHEM. Results Two‐hundred matched glucose measurements were collected from 8 neonatal foals. The mean bias (95% limits of agreement) between CGMS and CHEM, CGMS and POC glucometer, and POC glucometer and CHEM was 3.97 mg/dL (−32.5 to 40.4), 18.2 mg/dL (−28.8 to 65.2), and 22.18 mg/dL (−9.3 to 53.67), respectively. The Pearson's correlation coefficient (r) was significantly correlated among all devices: GCMS and CHEM (r = 0.81), CGMS and POC glucometer (r = 0.77) and POC glucometer‐CHEM (r = 0.92). Conclusions and Clinical Importance Within the blood glucose concentration ranges in this study (78‐212 mg/dL), CGMS measurements were significantly correlated with CHEM, suggesting that it is an acceptable method to provide meaningful, immediate, and continuous glucose concentration measurements in neonatal foals while eliminating the need for repeated restraint and blood collection.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, D. W. E. (2021). Evaluation of a continuous glucose monitoring system in neonatal foals. https://doi.org/10.1111/jvim.16186

MLA

al, David Wong et. "Evaluation of a continuous glucose monitoring system in neonatal foals." 2021. https://doi.org/10.1111/jvim.16186.

Chicago

al, David Wong et. 2021. "Evaluation of a continuous glucose monitoring system in neonatal foals.". https://doi.org/10.1111/jvim.16186.

Harvard

al, D. W. E. 2021, Evaluation of a continuous glucose monitoring system in neonatal foals, Oxford University Press, available at: https://doi.org/10.1111/jvim.16186 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Evaluation of a continuous glucose monitoring system in neonatal foals
Autore / collaboratori
David Wong et al
Editore
Oxford University Press
Anno di pubblicazione
2021
ISSN
0891-6640
ISSN
0891-6640
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato