Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo

Accuracy of working length measurement by Raypex 6: Electronic apex locator versus actual measurements under stereomicroscope

Peker Begum Unsal et al · Balkan Stomatological Society · 2022

Acceso abierto al texto completo
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

DOAJ DOAJ Articles
Entrar por DOAJ
Acceso principal

Acceso abierto al texto completo

Texto completo identificado como acceso abierto.
Abrir texto

Resumen

Descripción general del contenido del recurso.

Background/Aim: This study aimed to evaluate the precision of the Raypex 6 apex locator in locating the apical constriction (AC) and major foramen (MF) during a root canal treatment compared with a microscopic evaluation. Another aim of the present study was to evaluate the accuracy of the Raypex 6 in the presence of different irrigating solutions (NaOCl, saline, EDTA, etidronic acid-HEBP). Material and Methods: One hundred and nine patients were included in this study and were randomly assigned into four groups according to the irrigation solution used; NaOCl, EDTA, HEBF and saline. Electronic MF (EMF) and AC (EAC) were measured by using Raypex 6. The teeth were extracted. The apical 3 mm of each canal was trimmed to expose the file tip. The samples were observed under a stereomicroscope, and the actual length of MF (ALMF) and AC (ALAC) were measured. The data were analyzed by using x2 test, and significance was set at P< 0.05. Results: The Raypex 6 was accurate 71.4% of the time to ±0.5mm and 93.3% of the time to ±1mm in determining the ALAC. While similar ALAC-EAC differences were observed in EDTA, NaOCl, and saline groups (p= 0.230), the highest differences were seen in the HEBP group (p= 1.000). The precision of Raypex 6 in determining the working length measurement depends on the type of irrigation. All solutions allowed reliable detection of AC. However, HEBF significantly increased the risk of overpreparation. Conclusions: Raypex 6 can be recommended for clinical use and its accuracy is not affected by the type of irrigant when locating MF.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, P. B. U. E. (2022). Accuracy of working length measurement by Raypex 6: Electronic apex locator versus actual measurements under stereomicroscope. https://doi.org/10.5937/bjdm2201015P

MLA

al, Peker Begum Unsal et. "Accuracy of working length measurement by Raypex 6: Electronic apex locator versus actual measurements under stereomicroscope." 2022. https://doi.org/10.5937/bjdm2201015P.

Chicago

al, Peker Begum Unsal et. 2022. "Accuracy of working length measurement by Raypex 6: Electronic apex locator versus actual measurements under stereomicroscope.". https://doi.org/10.5937/bjdm2201015P.

Harvard

al, P. B. U. E. 2022, Accuracy of working length measurement by Raypex 6: Electronic apex locator versus actual measurements under stereomicroscope, Balkan Stomatological Society, available at: https://doi.org/10.5937/bjdm2201015P [Accessed 5 Aug. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Accuracy of working length measurement by Raypex 6: Electronic apex locator versus actual measurements under stereomicroscope
Autor / colaboradores
Peker Begum Unsal et al
Editorial
Balkan Stomatological Society
Año de publicación
2022
ISSN
2335-0245
ISSN
2335-0245
Idioma
Inglés

Materias

Explorá otros recursos relacionados a partir de estas materias.

Copiado