Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Automated echocardiographic left ventricular dimension assessment in dogs using artificial intelligence: Development and validation

Catherine C. Stowell et al · Oxford University Press · 2024

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

Questa pubblicazione seriale contiene 149 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Abstract Background Artificial intelligence (AI) could improve accuracy and reproducibility of echocardiographic measurements in dogs. Hypothesis A neural network can be trained to measure echocardiographic left ventricular (LV) linear dimensions in dogs. Animals Training dataset: 1398 frames from 461 canine echocardiograms from a single specialist center. Validation: 50 additional echocardiograms from the same center. Methods Training dataset: a right parasternal 4‐chamber long axis frame from each study, labeled by 1 of 18 echocardiographers, marking anterior and posterior points of the septum and free wall. Validation Dataset End‐diastolic and end‐systolic frames from 50 studies, annotated twice (blindly) by 13 experts, producing 26 measurements of each site from each frame. The neural network also made these measurements. We quantified its accuracy as the deviation from the expert consensus, using the individual‐expert deviation from consensus as context for acceptable variation. The deviation of the AI measurement away from the expert consensus was assessed on each individual frame and compared with the root‐mean‐square‐variation of the individual expert opinions away from that consensus. Results For the septum in end‐diastole, individual expert opinions deviated by 0.12 cm from the consensus, while the AI deviated by 0.11 cm (P = .61). For LVD, the corresponding values were 0.20 cm for experts and 0.13 cm for AI (P = .65); for the free wall, experts 0.20 cm, AI 0.13 cm (P < .01). In end‐systole, there were no differences between individual expert and AI performances. Conclusions and Clinical Importance An artificial intelligence network can be trained to adequately measure linear LV dimensions, with performance indistinguishable from that of experts.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, C. C. S. E. (2024). Automated echocardiographic left ventricular dimension assessment in dogs using artificial intelligence: Development and validation. https://doi.org/10.1111/jvim.17012

MLA

al, Catherine C. Stowell et. "Automated echocardiographic left ventricular dimension assessment in dogs using artificial intelligence: Development and validation." 2024. https://doi.org/10.1111/jvim.17012.

Chicago

al, Catherine C. Stowell et. 2024. "Automated echocardiographic left ventricular dimension assessment in dogs using artificial intelligence: Development and validation.". https://doi.org/10.1111/jvim.17012.

Harvard

al, C. C. S. E. 2024, Automated echocardiographic left ventricular dimension assessment in dogs using artificial intelligence: Development and validation, Oxford University Press, available at: https://doi.org/10.1111/jvim.17012 [Accessed 5 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Automated echocardiographic left ventricular dimension assessment in dogs using artificial intelligence: Development and validation
Autore / collaboratori
Catherine C. Stowell et al
Editore
Oxford University Press
Anno di pubblicazione
2024
ISSN
0891-6640
ISSN
0891-6640
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato