Design and Experimentation of Automatic Tidying and Sorting Mechanism for Blood Collection Needles in Stacking State

Junhua Tong et al · KeAi Communications Co., Ltd · 2019

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Abstract Disposable blood collection needles become severely intertwined and hooked during stacking, and thus individually feeding disposable blood collection needles during mechanical packaging is difficult. Based on the physical characteristics of the blood collection needles during the stacking state, this study designed an automatic tidying and sorting mechanism by combining compound vibration, sorting, and conveying. During the feeding process, the compound vibration-type material-tidying mechanism tidies 20‒30 blood collection needles first; then, the material sorting and conveying mechanism transports the tidied blood collection needles individually. The orthogonal testing of the automatic material tidying process shows that various experimental factors are ranked by the significance level of the effect on the tidying process and the significance ranking is as follows: vertical vibration frequency > horizontal amplitude > vertical amplitude > horizontal vibration frequency. Experiments were performed after analyzing the optimal combination. The results demonstrate that when the horizontal vibration frequency is 1.7 Hz, the horizontal amplitude is 150 mm, vertical vibration frequency is 1.3 Hz, vertical amplitude is 30 mm, and material length after tidying is 265 mm. The automatic sorting and conveying experiment shows the effect of various experimental factors on the feed rate of the material, where the significance level of the effect is ranked as follows: vibration frequency > material quantity > channel dip angle. The experimental results show that when the number of materials is 25, the channel dip angle is 12°, and vibration frequency is 52.5 Hz. The material delivery efficiency reaches 0.51 s/root, meeting the requirement of five channels for 80000 root/day feeding efficiency. The study can provide reference for the realization of automatic feeding of large aspect ratio flexible materials in similar stacking state.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, J. T. E. (2019). Design and Experimentation of Automatic Tidying and Sorting Mechanism for Blood Collection Needles in Stacking State. https://doi.org/10.1186/s10033-019-0387-x

MLA

al, Junhua Tong et. "Design and Experimentation of Automatic Tidying and Sorting Mechanism for Blood Collection Needles in Stacking State." 2019. https://doi.org/10.1186/s10033-019-0387-x.

Chicago

al, Junhua Tong et. 2019. "Design and Experimentation of Automatic Tidying and Sorting Mechanism for Blood Collection Needles in Stacking State.". https://doi.org/10.1186/s10033-019-0387-x.

Harvard

al, J. T. E. 2019, Design and Experimentation of Automatic Tidying and Sorting Mechanism for Blood Collection Needles in Stacking State, KeAi Communications Co, Ltd, available at: https://doi.org/10.1186/s10033-019-0387-x [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Design and Experimentation of Automatic Tidying and Sorting Mechanism for Blood Collection Needles in Stacking State
Autore / collaboratori
Junhua Tong et al
Editore
KeAi Communications Co., Ltd
Anno di pubblicazione
2019
ISSN
1000-9345
ISSN
1000-9345
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato