Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Accuracy of a magnetic resonance imaging‐based 3D printed stereotactic brain biopsy device in dogs

Sarah Gutmann et al · Oxford University Press · 2020

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

Questa pubblicazione seriale contiene 149 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Abstract Background Brain biopsy of intracranial lesions is often necessary to determine specific therapy. The cost of the currently used stereotactic rigid frame and optical tracking systems for brain biopsy in dogs is often prohibitive or accuracy is not sufficient for all types of lesion. Objectives To evaluate the application accuracy of an inexpensive magnetic resonance imaging‐based personalized, 3D printed brain biopsy device. Animals Twenty‐two dog heads from cadavers were separated into 2 groups according to body weight (<15 kg, >20 kg). Methods Experimental study. Two target points in each cadaver head were used (target point 1: caudate nucleus, target point 2: piriform lobe). Comparison between groups was performed using the independent Student's t test or the nonparametric Mann‐Whitney U Test. Results The total median target point deviation was 0.83 mm (range 0.09‐2.76 mm). The separate median target point deviations for target points 1 and 2 in all dogs were 0.57 mm (range: 0.09‐1.25 mm) and 0.85 mm (range: 0.14‐2.76 mm), respectively. Conclusion and Clinical Importance This magnetic resonance imaging‐based 3D printed stereotactic brain biopsy device achieved an application accuracy that was better than the accuracy of most brain biopsy systems that are currently used in veterinary medicine. The device can be applied to every size and shape of skull and allows precise positioning of brain biopsy needles in dogs.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, S. G. E. (2020). Accuracy of a magnetic resonance imaging‐based 3D printed stereotactic brain biopsy device in dogs. https://doi.org/10.1111/jvim.15739

MLA

al, Sarah Gutmann et. "Accuracy of a magnetic resonance imaging‐based 3D printed stereotactic brain biopsy device in dogs." 2020. https://doi.org/10.1111/jvim.15739.

Chicago

al, Sarah Gutmann et. 2020. "Accuracy of a magnetic resonance imaging‐based 3D printed stereotactic brain biopsy device in dogs.". https://doi.org/10.1111/jvim.15739.

Harvard

al, S. G. E. 2020, Accuracy of a magnetic resonance imaging‐based 3D printed stereotactic brain biopsy device in dogs, Oxford University Press, available at: https://doi.org/10.1111/jvim.15739 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Accuracy of a magnetic resonance imaging‐based 3D printed stereotactic brain biopsy device in dogs
Autore / collaboratori
Sarah Gutmann et al
Editore
Oxford University Press
Anno di pubblicazione
2020
ISSN
0891-6640
ISSN
0891-6640
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato