Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Acurácia da histerossonografia versus ultrassonografia transvaginal em mulheres inférteis candidatas às técnicas de reprodução assistida Sonohysterography accuracy versus transvaginal ultrasound in infertile women candidate to assisted reproduction techniques

João Rocha Vilela et al · Federação Brasileira das Sociedades de Ginecologia e Obstetrícia · 2012

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A FEBRASGO e o Novo Ano

Questa pubblicazione seriale contiene 195 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

OBJETIVO: Comparar a acurácia diagnóstica da histerossonografia (HSN) com a da ultrassonografia transvaginal convencional (USG) na avaliação da cavidade uterina de mulheres inférteis candidatas às técnicas de reprodução assistida (TRA). MÉTODOS: Realizou-se estudo transversal comparativo com 120 mulheres inférteis candidatas à TRA, acompanhadas no Centro de Reprodução Assistida (CRA) do Hospital Regional da Asa Sul (HRAS), Brasília - DF, no período compreendido entre agosto de 2009 e novembro de 2010. A HSN foi realizada com infusão de soro fisiológico em sistema fechado. Comparou-se o achado da HSN com o resultado da USG prévia. A cavidade uterina foi considerada anormal quando se visualizava: endométrio com espessura superior à esperada para a fase do ciclo; pólipo endometrial; mioma submucoso e alteração do formato da cavidade do útero. A análise estatística foi feita utilizando-se frequências absolutas, valores percentuais e o teste &#967;² com nível de significância de 5%. RESULTADOS: Observamos que 92 (76,7%) mulheres inférteis, candidatas à TRA, apresentavam cavidade uterina normal pela HSN e em 28 (23,3%) foram detectadas as seguintes alterações: 15 pólipos (12,5%), nove alterações no formato da cavidade uterina (7,5%), 6 miomas submucosos (5%), 4 espessura endometrial anormal (3,3%) para a fase do ciclo menstrual e 2 septos uterinos (1,7%); 5 mulheres apresentavam mais de uma alteração (4,2%). Enquanto a USG observou alterações da cavidade uterina apenas em 5 (4,2%) mulheres, a HSN confirmou 4 das 5 alterações detectadas pela USG e detectou alterações na cavidade uterina em outras 24 mulheres que não tinham sido detectadas na USG, ou seja, a HSN foi capaz de detectar mais alterações na cavidade uterina do que a USG, com diferença significativa (p=0,002). CONCLUSÃO: A HSN tem maior acurácia que a USG na avaliação da cavidade uterina, neste grupo de mulheres inférteis candidatas às TRA. A HSN poderá ser facilmente incorporada à propedêutica das candidatas às TRA e contribuir para reduzir as falhas de implantação embrionária.<br>PURPOSE: To compare the diagnostic accuracy of sonohysterography (HSN) and conventional transvaginal ultrasound (USG) in assessing the uterine cavity of infertile women candidate to assisted reproduction techniques (ART). METHODS: Comparative cross-sectional study with 120 infertile women candidate to ART, assisted at Centro de Reprodução Assistida (CRA) of Hospital Regional da Asa Sul (HRAS), Brasília - DF, from August 2009 to November 2010. Sonohysterography was performed with saline solution infusion in a close system. The sonohysterography finding was compared to previous USG results. The uterine cavity was considered abnormal when the endometrium was found to be thicker than expected during the menstrual cycle and when an endometrial polyp, a submucous myoma and an abnormal shape of the uterine cavity were observed. The statistical analysis was done using absolute frequencies, percentage values and the &#967;², with the level of significance set at 5%. RESULTS: HSN revealed that 92 (76.7%) infertile women candidate to ART had a normal uterine cavity, while 28 (23.3%) had the following abnormalities: 15 polyps (12.5%), 9 cases of abnormal shape of the uterine cavity (7.5%), 6 submucous myomas (5%), 4 cases of inadequate endometrial thickness for the menstrual cycle phase (3.3%), and 2 cases of uterine septum (1.7%); 5 women presented more than one abnormality (4.2%). While USG showed alteration in the cavity only in 5 (4.2%) women, the sonohysterography confirmed 4 out of the 5 abnormalities shown by USG and detected an abnormal uterine cavity in 24 other women, who had not been detected by USG. This means that sonohysterography was able to detect more abnormalities in the uterine cavity than USG, with a statistically significant difference (p=0.002). CONCLUSION: The sonohysterography was more accurate than USG in the assessment of the uterine cavity of this cohort of infertile women candidate to ART. The sonohysterography can be easily incorporated into the investigation of these women and contribute to reducing embryo implantation failures.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, J. R. V. E. (2012). Acurácia da histerossonografia versus ultrassonografia transvaginal em mulheres inférteis candidatas às técnicas de reprodução assistida Sonohysterography accuracy versus transvaginal ultrasound in infertile women candidate to assisted reproduction techniques. https://doi.org/10.1590/S0100-72032012000300006

MLA

al, João Rocha Vilela et. "Acurácia da histerossonografia versus ultrassonografia transvaginal em mulheres inférteis candidatas às técnicas de reprodução assistida Sonohysterography accuracy versus transvaginal ultrasound in infertile women candidate to assisted reproduction techniques." 2012. https://doi.org/10.1590/S0100-72032012000300006.

Chicago

al, João Rocha Vilela et. 2012. "Acurácia da histerossonografia versus ultrassonografia transvaginal em mulheres inférteis candidatas às técnicas de reprodução assistida Sonohysterography accuracy versus transvaginal ultrasound in infertile women candidate to assisted reproduction techniques.". https://doi.org/10.1590/S0100-72032012000300006.

Harvard

al, J. R. V. E. 2012, Acurácia da histerossonografia versus ultrassonografia transvaginal em mulheres inférteis candidatas às técnicas de reprodução assistida Sonohysterography accuracy versus transvaginal ultrasound in infertile women candidate to assisted reproduction techniques, Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, available at: https://doi.org/10.1590/S0100-72032012000300006 [Accessed 6 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Acurácia da histerossonografia versus ultrassonografia transvaginal em mulheres inférteis candidatas às técnicas de reprodução assistida Sonohysterography accuracy versus transvaginal ultrasound in infertile women candidate to assisted reproduction techniques
Autore / collaboratori
João Rocha Vilela et al
Editore
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
Anno di pubblicazione
2012
ISSN
0100-7203
ISSN
0100-7203
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato