Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Comparative radiopacity of pediatric dental restorative materials

Kuter Berna et al · Balkan Stomatological Society · 2022

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Background/Aim: Radiopacity of dental restorative materials is significant to detect secondary caries, overhangs, and voids. This study aimed to evaluate whether radiopacity of dental restorative materials used in pediatric dentistry was sufficient. Material and Methods: Specimens of 2 mm thickness and 4 mm diameter were prepared in the plastic molds. Six composite materials, one compomer material, and one conventional glass ionomer cement were used and three specimens of each material were prepared. Three radiographs were taken from dental restorative materials and aluminum step wedge. Digital images obtained were recorded. Mean gray values of the dental restorative materials and aluminum step wedge were measured on digital radiographs. Results: All composite resins displayed higher radiopacity values than an equal thickness of 2 mm Al. Posterior composite (201.62±1.99 MGV) showed higher radiopacity value than the anterior composite (86.19 ±1.45 MGV). There was no significant difference in radiopacity values of different shades of the same composite. There was no significant difference in radiopacity values between glass ionomer cement and compomer. Glass ionomer cement showed higher radiopacity value (8.11 mm Al) than anterior composite (5.31 mm Al). Conclusions: Radiopacity values of dental materials used in this study were sufficient. Both resin materials and the glass ionomer cement had sufficient radiopacity values. Posterior composite showed the highest radiopacity value. Radiopacity values were not affected by different shades.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, K. B. E. (2022). Comparative radiopacity of pediatric dental restorative materials. https://doi.org/10.5937/bjdm2201047K

MLA

al, Kuter Berna et. "Comparative radiopacity of pediatric dental restorative materials." 2022. https://doi.org/10.5937/bjdm2201047K.

Chicago

al, Kuter Berna et. 2022. "Comparative radiopacity of pediatric dental restorative materials.". https://doi.org/10.5937/bjdm2201047K.

Harvard

al, K. B. E. 2022, Comparative radiopacity of pediatric dental restorative materials, Balkan Stomatological Society, available at: https://doi.org/10.5937/bjdm2201047K [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Comparative radiopacity of pediatric dental restorative materials
Autore / collaboratori
Kuter Berna et al
Editore
Balkan Stomatological Society
Anno di pubblicazione
2022
ISSN
2335-0245
ISSN
2335-0245
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato