Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Pencil-beam scanning catheter for intracoronary optical coherence tomography

Jiqiang Kang et al · Editorial Office of Opto-Electronic Journals Group, Institute of Optics and Electronics, CAS, China · 2022

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Current gradient-index (GRIN) lens based proximal-driven intracoronary optical coherence tomography (ICOCT) probes consist of a spacer and a GRIN lens with large gradient constant. This design provides great flexibility to control beam profiles, but the spacer length should be well controlled to obtain desired beam profiles and thus it sets an obstacle in mass catheter fabrication. Besides, although GRIN lens with large gradient constant can provide tight focus spot, it has short depth of focus and fast-expanded beam which leads to poor lateral resolution for deep tissue. In this paper, a type of spacer-removed probe is demonstrated with a small gradient constant GRIN lens. This design simplifies the fabrication process and is suitable for mass production. The output beam of the catheter is a narrow nearly collimated light beam, referred to as pencil beam here. The full width at half maximum beam size varies from 35.1 µm to 75.3 µm in air over 3-mm range. Probe design principles are elaborated with probe/catheter fabrication and performance test. The in vivo imaging of the catheter was verified by a clinical ICOCT system. Those results prove that this novel pencil-beam scanning catheter is potentially a good choice for ICOCT systems.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, J. K. E. (2022). Pencil-beam scanning catheter for intracoronary optical coherence tomography. https://doi.org/10.29026/oea.2022.200050

MLA

al, Jiqiang Kang et. "Pencil-beam scanning catheter for intracoronary optical coherence tomography." 2022. https://doi.org/10.29026/oea.2022.200050.

Chicago

al, Jiqiang Kang et. 2022. "Pencil-beam scanning catheter for intracoronary optical coherence tomography.". https://doi.org/10.29026/oea.2022.200050.

Harvard

al, J. K. E. 2022, Pencil-beam scanning catheter for intracoronary optical coherence tomography, Editorial Office of Opto-Electronic Journals Group, Institute of Optics and Electronics, CAS, China, available at: https://doi.org/10.29026/oea.2022.200050 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Pencil-beam scanning catheter for intracoronary optical coherence tomography
Autore / collaboratori
Jiqiang Kang et al
Editore
Editorial Office of Opto-Electronic Journals Group, Institute of Optics and Electronics, CAS, China
Anno di pubblicazione
2022
ISSN
2096-4579
ISSN
2096-4579
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato