Evaluation of the relationship between masseter muscle electromyography and occlusal force in a head operated pointing device

Kaho Ishikawa et al · Society for Science and Technology · 2024

Material complementario disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

DOAJ DOAJ Articles
Entrar por DOAJ
Acceso principal

Material complementario disponible

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Abrir material

Resumen

Descripción general del contenido del recurso.

Recently, the demand for nursing care services has been increasing in Japan due to the aging of the population. Addressing this increase in demand is an urgent issue, necessitating a qualitative shift in nursing care services. Proposals for new caregiving support measures utilizing welfare equipment are deemed effective in addressing such an issue. Thus, a Human Interface-type pointing device (Face-input Pointing Device: FPD) has been developed to promote the self-support of individuals requiring caregiving. The FPD can be controlled only by head movement, utilizing the head posture angle and masseter muscle electromyography (EMG) as control signals. However, aging may affect the operation of FPD due to a decrease in occlusal force and masseter muscle EMG potentials. Namely, investigations targeting a wide age range are necessary. In this study, the reliability of FPD operation by age group was evaluated. Test subjects were males in their 10’s to 30’s and 40’s to 50’s. In the experiment, masticatory ability (Occlusal force, occlusal pressure, occlusal contact area, etc.) measurement, masseter muscle EMG measurement and FPD operational test were conducted. The effect of aging was analyzed based on the relationship between EMG potentials and masticatory ability. In the operation test, the operational reliability of the FPD was evaluated based on the task success rate. As a result, 96.6 % of test subjects did not fall into the low occlusal force category, and task success rates were high (> 90 %), indicating that people in 10’s to 50’s are suitable candidates for FPD adaptation. On the other hand, when targeting older individuals with reduced masseter muscle EMG signals, distinguishing between EMG signals and noise may become challenging using current electromyographs. Therefore, further noise reduction measures in electromyographs for the elderly are necessary.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, K. I. E. (2024). Evaluation of the relationship between masseter muscle electromyography and occlusal force in a head operated pointing device. https://doi.org/10.11425/sst.13.23

MLA

al, Kaho Ishikawa et. "Evaluation of the relationship between masseter muscle electromyography and occlusal force in a head operated pointing device." 2024. https://doi.org/10.11425/sst.13.23.

Chicago

al, Kaho Ishikawa et. 2024. "Evaluation of the relationship between masseter muscle electromyography and occlusal force in a head operated pointing device.". https://doi.org/10.11425/sst.13.23.

Harvard

al, K. I. E. 2024, Evaluation of the relationship between masseter muscle electromyography and occlusal force in a head operated pointing device, Society for Science and Technology, available at: https://doi.org/10.11425/sst.13.23 [Accessed 5 Aug. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Evaluation of the relationship between masseter muscle electromyography and occlusal force in a head operated pointing device
Autor / colaboradores
Kaho Ishikawa et al
Editorial
Society for Science and Technology
Año de publicación
2024
ISSN
2186-4942
ISSN
2186-4942
Idioma
Inglés
Copiado