Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Evaluation of the relationship between masseter muscle electromyography and occlusal force in a head operated pointing device

Kaho Ishikawa et al · Society for Science and Technology · 2024

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Recently, the demand for nursing care services has been increasing in Japan due to the aging of the population. Addressing this increase in demand is an urgent issue, necessitating a qualitative shift in nursing care services. Proposals for new caregiving support measures utilizing welfare equipment are deemed effective in addressing such an issue. Thus, a Human Interface-type pointing device (Face-input Pointing Device: FPD) has been developed to promote the self-support of individuals requiring caregiving. The FPD can be controlled only by head movement, utilizing the head posture angle and masseter muscle electromyography (EMG) as control signals. However, aging may affect the operation of FPD due to a decrease in occlusal force and masseter muscle EMG potentials. Namely, investigations targeting a wide age range are necessary. In this study, the reliability of FPD operation by age group was evaluated. Test subjects were males in their 10’s to 30’s and 40’s to 50’s. In the experiment, masticatory ability (Occlusal force, occlusal pressure, occlusal contact area, etc.) measurement, masseter muscle EMG measurement and FPD operational test were conducted. The effect of aging was analyzed based on the relationship between EMG potentials and masticatory ability. In the operation test, the operational reliability of the FPD was evaluated based on the task success rate. As a result, 96.6 % of test subjects did not fall into the low occlusal force category, and task success rates were high (> 90 %), indicating that people in 10’s to 50’s are suitable candidates for FPD adaptation. On the other hand, when targeting older individuals with reduced masseter muscle EMG signals, distinguishing between EMG signals and noise may become challenging using current electromyographs. Therefore, further noise reduction measures in electromyographs for the elderly are necessary.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, K. I. E. (2024). Evaluation of the relationship between masseter muscle electromyography and occlusal force in a head operated pointing device. https://doi.org/10.11425/sst.13.23

MLA

al, Kaho Ishikawa et. "Evaluation of the relationship between masseter muscle electromyography and occlusal force in a head operated pointing device." 2024. https://doi.org/10.11425/sst.13.23.

Chicago

al, Kaho Ishikawa et. 2024. "Evaluation of the relationship between masseter muscle electromyography and occlusal force in a head operated pointing device.". https://doi.org/10.11425/sst.13.23.

Harvard

al, K. I. E. 2024, Evaluation of the relationship between masseter muscle electromyography and occlusal force in a head operated pointing device, Society for Science and Technology, available at: https://doi.org/10.11425/sst.13.23 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Evaluation of the relationship between masseter muscle electromyography and occlusal force in a head operated pointing device
Autore / collaboratori
Kaho Ishikawa et al
Editore
Society for Science and Technology
Anno di pubblicazione
2024
ISSN
2186-4942
ISSN
2186-4942
Lingua
Inglés
Copiato