Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Kinematic Calibration of a Six-Legged Walking Machine Tool

Jimu Liu et al · KeAi Communications Co., Ltd · 2022

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Abstract This paper presents the kinematic calibration of a novel six-legged walking machine tool comprising a six-legged mobile robot integrated with a parallel manipulator on the body. Each leg of the robot is a 2-universal-prismatic-spherical (UPS) and UP parallel mechanism, and the manipulator is a 6-PSU parallel mechanism. The error models of both subsystems are derived according to their inverse kinematics. The objective function for each kinematic limb is formulated as the inverse kinematic residual, i.e., the deviation between the actual and computed joint coordinates. The hip center of each leg is first identified via sphere fitting, and the other kinematic parameters are identified by solving the objective function for each limb individually using the least-squares method. Thus, the kinematic parameters are partially decoupled, and the complexities of the error models are reduced. A calibration method is proposed for the legged robot to overcome the lack of a fixed base on the ground. A calibration experiment is conducted to validate the proposed method, where a laser tracker is used as the measurement equipment. The kinematic parameters of the entire robot are identified, and the motion accuracy of each leg and that of the manipulator are significantly improved after calibration. Validation experiments are performed to evaluate the positioning and trajectory errors of the six-legged walking machine tool. The results indicate that the kinematic calibration of the legs and manipulator improves not only the motion accuracy of each individual subsystem but also the cooperative motion accuracy among the subsystems.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, J. L. E. (2022). Kinematic Calibration of a Six-Legged Walking Machine Tool. https://doi.org/10.1186/s10033-022-00688-2

MLA

al, Jimu Liu et. "Kinematic Calibration of a Six-Legged Walking Machine Tool." 2022. https://doi.org/10.1186/s10033-022-00688-2.

Chicago

al, Jimu Liu et. 2022. "Kinematic Calibration of a Six-Legged Walking Machine Tool.". https://doi.org/10.1186/s10033-022-00688-2.

Harvard

al, J. L. E. 2022, Kinematic Calibration of a Six-Legged Walking Machine Tool, KeAi Communications Co, Ltd, available at: https://doi.org/10.1186/s10033-022-00688-2 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Kinematic Calibration of a Six-Legged Walking Machine Tool
Autore / collaboratori
Jimu Liu et al
Editore
KeAi Communications Co., Ltd
Anno di pubblicazione
2022
ISSN
1000-9345
ISSN
1000-9345
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato