Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Spatiotemporal hemodynamic monitoring via configurable skin-like microfiber Bragg grating group

Hengtian Zhu et al · Editorial Office of Opto-Electronic Journals Group, Institute of Optics and Electronics, CAS, China · 2023

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Systemic blood circulation is one of life activity’s most important physiological functions. Continuous noninvasive hemodynamic monitoring is essential for the management of cardiovascular status. However, it is difficult to achieve systemic hemodynamic monitoring with the daily use of current devices due to the lack of multichannel and time-synchronized operation capability over the whole body. Here, we utilize a soft microfiber Bragg grating group to monitor spatiotemporal hemodynamics by taking advantage of the high sensitivity, electromagnetic immunity, and great temporal synchronization between multiple remote sensor nodes. A continuous systemic hemodynamic measurement technique is developed using all-mechanical physiological signals, such as ballistocardiogram signals and pulse waves, to illustrate the actual mechanical process of blood circulation. Multiple hemodynamic parameters, such as systemic pulse transit time, heart rate, blood pressure, and peripheral resistance, are monitored using skin-like microfiber Bragg grating patches conformally attached at different body locations. Relying on the soft microfiber Bragg grating group, the spatiotemporal hemodynamic monitoring technique opens up new possibilities in clinical medical diagnosis and daily health management.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, H. Z. E. (2023). Spatiotemporal hemodynamic monitoring via configurable skin-like microfiber Bragg grating group. https://doi.org/10.29026/oea.2023.230018

MLA

al, Hengtian Zhu et. "Spatiotemporal hemodynamic monitoring via configurable skin-like microfiber Bragg grating group." 2023. https://doi.org/10.29026/oea.2023.230018.

Chicago

al, Hengtian Zhu et. 2023. "Spatiotemporal hemodynamic monitoring via configurable skin-like microfiber Bragg grating group.". https://doi.org/10.29026/oea.2023.230018.

Harvard

al, H. Z. E. 2023, Spatiotemporal hemodynamic monitoring via configurable skin-like microfiber Bragg grating group, Editorial Office of Opto-Electronic Journals Group, Institute of Optics and Electronics, CAS, China, available at: https://doi.org/10.29026/oea.2023.230018 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Spatiotemporal hemodynamic monitoring via configurable skin-like microfiber Bragg grating group
Autore / collaboratori
Hengtian Zhu et al
Editore
Editorial Office of Opto-Electronic Journals Group, Institute of Optics and Electronics, CAS, China
Anno di pubblicazione
2023
ISSN
2096-4579
ISSN
2096-4579
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato