Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo

The validity of a running motion analysis device using inertial navigation system

Yudai Furukawa et al · Society for Science and Technology · 2017

Acceso abierto disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

DOAJ DOAJ Articles
Entrar por DOAJ
Acceso principal

Acceso abierto disponible

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Abrir recurso

Resumen

Descripción general del contenido del recurso.

The purpose of this study was to analyze the traveling motion by a running motion analysis device (sensor device) using an inertial navigation system with a proprietary triaxial acceleration sensor and gyro sensor and 3 dimensional motion analysis system (VICON). The validity of the sensor devise as a motion analysis device was examined by comparing the analysis results of the running motion. As a result, the intraclass correlation coefficient (ICC) was 0.9 or more at speed, vertical motion, contact time, brake, landing angle and kicking out angle. The degree of agreement between the above two analysis index values between the two devices was regarded as excellent. By Bland-Altman analysis, it was recognized that the degree of coincidence of each analysis index value was high, and the difference was confirmed to be within the error range. In some items, the sensor device was more accurate than VICON and the possibility of measurement could be considered sufficiently. From the above results, it can be said that the accuracy of the sensor device developed independently and the accuracy of the algorithm used for motion analysis were recognized, and the validity as a motion analysis device was recognized.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, Y. F. E. (2017). The validity of a running motion analysis device using inertial navigation system. https://doi.org/10.11425/sst.6.47

MLA

al, Yudai Furukawa et. "The validity of a running motion analysis device using inertial navigation system." 2017. https://doi.org/10.11425/sst.6.47.

Chicago

al, Yudai Furukawa et. 2017. "The validity of a running motion analysis device using inertial navigation system.". https://doi.org/10.11425/sst.6.47.

Harvard

al, Y. F. E. 2017, The validity of a running motion analysis device using inertial navigation system, Society for Science and Technology, available at: https://doi.org/10.11425/sst.6.47 [Accessed 5 Aug. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
The validity of a running motion analysis device using inertial navigation system
Autor / colaboradores
Yudai Furukawa et al
Editorial
Society for Science and Technology
Año de publicación
2017
ISSN
2186-4942
ISSN
2186-4942
Idioma
Inglés
Copiado