Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

The validity of a running motion analysis device using inertial navigation system

Yudai Furukawa et al · Society for Science and Technology · 2017

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

The purpose of this study was to analyze the traveling motion by a running motion analysis device (sensor device) using an inertial navigation system with a proprietary triaxial acceleration sensor and gyro sensor and 3 dimensional motion analysis system (VICON). The validity of the sensor devise as a motion analysis device was examined by comparing the analysis results of the running motion. As a result, the intraclass correlation coefficient (ICC) was 0.9 or more at speed, vertical motion, contact time, brake, landing angle and kicking out angle. The degree of agreement between the above two analysis index values between the two devices was regarded as excellent. By Bland-Altman analysis, it was recognized that the degree of coincidence of each analysis index value was high, and the difference was confirmed to be within the error range. In some items, the sensor device was more accurate than VICON and the possibility of measurement could be considered sufficiently. From the above results, it can be said that the accuracy of the sensor device developed independently and the accuracy of the algorithm used for motion analysis were recognized, and the validity as a motion analysis device was recognized.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, Y. F. E. (2017). The validity of a running motion analysis device using inertial navigation system. https://doi.org/10.11425/sst.6.47

MLA

al, Yudai Furukawa et. "The validity of a running motion analysis device using inertial navigation system." 2017. https://doi.org/10.11425/sst.6.47.

Chicago

al, Yudai Furukawa et. 2017. "The validity of a running motion analysis device using inertial navigation system.". https://doi.org/10.11425/sst.6.47.

Harvard

al, Y. F. E. 2017, The validity of a running motion analysis device using inertial navigation system, Society for Science and Technology, available at: https://doi.org/10.11425/sst.6.47 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
The validity of a running motion analysis device using inertial navigation system
Autore / collaboratori
Yudai Furukawa et al
Editore
Society for Science and Technology
Anno di pubblicazione
2017
ISSN
2186-4942
ISSN
2186-4942
Lingua
Inglés
Copiato