Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo

Ultra-sonografia transvaginal com doppler colorido para seleção das pacientes para tratamento conservador da gravidez ectópica íntegra Transvaginal ultrasonography with color doppler to select the patients for conservative treatment of unruptured ectopic pregnancy

Julio Elito Junior et al · Federação Brasileira das Sociedades de Ginecologia e Obstetrícia · 1999

Material complementario disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.
Publicación seriada

A FEBRASGO e o Novo Ano

Esta publicación seriada contiene 195 contenidos relacionados.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

DOAJ DOAJ Articles
Entrar por DOAJ
Acceso principal

Material complementario disponible

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Abrir material

Resumen

Descripción general del contenido del recurso.

Objetivo: avaliar a eficiência da ultra-sonografia (US) transvaginal com Doppler colorido para a previsão dos resultados do tratamento sistêmico da gravidez ectópica íntegra com dose única de metotrexato. Pacientes e método: vinte pacientes com diagnóstico de gravidez ectópica foram incluídas no estudo. Os critérios de inclusão foram: estabilidade hemodinâmica, massa anexial com diâmetro < 5,0 cm e queda dos títulos de beta-hCG inferior a 15% num intervalo de 24 horas. Foram excluídas as pacientes que apresentaram doença hepática ou renal ou discrasias sangüíneas. O acompanhamento foi realizado com dosagens seriadas de beta-hCG nos dias 4 e 7 após instituído o tratamento, e semanalmente até que os títulos de beta-hCG se tornassem negativos. As pacientes foram classificadas em três conjuntos, conforme a US com doppler colorido: elevado risco (fluxo trofoblástico acometendo mais de 2/3 da massa anexial), médio risco (quando o fluxo trofoblástico comprometia de 1/3 a 2/3 do anel tubário) e de baixo risco (fluxos que acometiam menos de 1/3 da massa anexial). Resultados: o sucesso do tratamento com dose única de MTX foi de 75% (15 pacientes); quando empregamos uma segunda dose, a percentagem de bons resultados foi de 85%. Confrontamos os resultados obtidos pela US transvaginal e Doppler colorido com o sucesso e o insucesso da terapêutica. Observamos que, das 20 pacientes, 4 apresentaram Doppler de elevado risco e todas evoluíram com fracasso, ao passo que em 16 casos o Doppler foi classificado como de médio ou baixo risco, sendo que destes 15 evoluíram com sucesso. Conclusão: a ultra-sonografia transvaginal com Doppler colorido classificado como de elevado risco indica situação desfavorável para o tratamento medicamentoso da gravidez ectópica com dose única de metotrexato, ao passo que o Doppler de médio e baixo risco indica situação favorável para o tratamento clínico, porém estes resultados devem sempre ser analisados em conjunto com a curva de evolução dos títulos de beta-hCG.<br>Purpose: to evaluate the efficacy of color Doppler in the prediction of results of the systemic treatment of unruptured ectopic pregnancy with a single dose of methotrexate. Methodology: twenty patients with a diagnosis of ectopic pregnancy were included in the study. The inclusion criteria were: hemodynamic stability, adnexal mass < 5.0 cm and decline of the titers of beta-hCG less than 15% in an interval of 24 h. The exclusion criteria were hepatic or renal disease and blood dyscrasias. Follow-up was by serial determinations of beta-hCG on days 4 and 7 after the beginning of the treatment, and weekly until the titers were negative. The patients were classified into 3 groups according to color Doppler: high risk (trophoblastic flow covering more than 2/3 of the mass), medium risk (when trophoblastic flow compromised 1/3 to 2/3 of tubal mass) and low risk (when trophoblastic flow covered less than 1/3 of the mass). Results: the success of the treatment with a single dose was 75% (15/20); when a second dose of MTX was used, the success rate was 85%. When comparing color Doppler with the results of the medical treatment, we had high risk in 4 patients and in all the treatment failed; medium and low risk in 16 patients, and in 15 the treatment was successful. Conclusion: color Doppler showing high risk indicated an unfavorable situation for the medical treatment with MTX, while medium and low risk in color doppler were favorable situations for the clinical treatment. However, these results should always be analyzed in association with the evolution curve of the beta-hCG titers.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, J. E. J. E. (1999). Ultra-sonografia transvaginal com doppler colorido para seleção das pacientes para tratamento conservador da gravidez ectópica íntegra Transvaginal ultrasonography with color doppler to select the patients for conservative treatment of unruptured ectopic pregnancy. https://doi.org/10.1590/S0100-72031999000300006

MLA

al, Julio Elito Junior et. "Ultra-sonografia transvaginal com doppler colorido para seleção das pacientes para tratamento conservador da gravidez ectópica íntegra Transvaginal ultrasonography with color doppler to select the patients for conservative treatment of unruptured ectopic pregnancy." 1999. https://doi.org/10.1590/S0100-72031999000300006.

Chicago

al, Julio Elito Junior et. 1999. "Ultra-sonografia transvaginal com doppler colorido para seleção das pacientes para tratamento conservador da gravidez ectópica íntegra Transvaginal ultrasonography with color doppler to select the patients for conservative treatment of unruptured ectopic pregnancy.". https://doi.org/10.1590/S0100-72031999000300006.

Harvard

al, J. E. J. E. 1999, Ultra-sonografia transvaginal com doppler colorido para seleção das pacientes para tratamento conservador da gravidez ectópica íntegra Transvaginal ultrasonography with color doppler to select the patients for conservative treatment of unruptured ectopic pregnancy, Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, available at: https://doi.org/10.1590/S0100-72031999000300006 [Accessed 5 Aug. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Ultra-sonografia transvaginal com doppler colorido para seleção das pacientes para tratamento conservador da gravidez ectópica íntegra Transvaginal ultrasonography with color doppler to select the patients for conservative treatment of unruptured ectopic pregnancy
Autor / colaboradores
Julio Elito Junior et al
Editorial
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
Año de publicación
1999
ISSN
0100-7203
ISSN
0100-7203
Idioma
Inglés

Materias

Explorá otros recursos relacionados a partir de estas materias.

Copiado