Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Pressão arterial e freqüência cardíaca avaliadas pela MAPA em primigestas durante o trabalho de parto e puerpério imediato Blood pressure and heart rate evaluated by ABPM in primigravid women during labor and early puerperium

Milton Marchioli et al · Federação Brasileira das Sociedades de Ginecologia e Obstetrícia · 2004

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A FEBRASGO e o Novo Ano

Questa pubblicazione seriale contiene 195 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

OBJETIVO: analisar os valores da pressão arterial e da freqüência cardíaca durante o trabalho de parto e puerpério imediato de primigestas normais. MÉTODOS: foram incluídas no estudo 60 parturientes, às quais foi aplicada a monitorização ambulatorial da pressão arterial (MAPA) com uso do aparelho modelo SpaceLabs 90207, durante o trabalho de parto e nas primeiras 12 horas após o mesmo. A pressão arterial e a freqüência cardíaca foram registradas a cada 15 minutos durante o trabalho de parto e na primeira hora após o parto, e a cada 30 minutos até a 12ª hora após o parto. Esses parâmetros foram avaliados em três momentos do trabalho de parto (com dilatação cervical até 7 cm, entre 8 cm e dilatação total e durante o período expulsivo) e em dois momentos do puerpério (na primeira e décima segunda hora). Primeiramente os resultados foram analisados sem levar em consideração o tipo de procedimento anestésico, e depois, dividindo-os em grupos conforme o tipo de procedimento realizado: anestesia local, analgesia peridural lombar e anestesia subaracnóidea. Para comparação dentro de cada grupo foram realizados análise de variância (ANOVA) e teste t de Student pareado e, entre os grupos, o teste t não-pareado. Foi considerado o limite de significância estatística de 5%. RESULTADOS: quando os resultados foram avaliados sem levar em consideração o procedimento anestésico, os valores médios da pressão arterial sistólica, registrados durante o trabalho de parto, foram significativamente mais elevados que no puerpério. Durante o trabalho de parto esses valores foram significativamente mais elevados nos períodos de dilatação final e expulsivo que no período de dilatação inicial e, na 12ª hora, inferiores ao da primeira hora após o parto. Os valores médios da pressão arterial diastólica registrados durante o trabalho de parto foram significativamente mais altos que no puerpério. Estes valores não apresentaram alteração durante os diferentes períodos do trabalho de parto ou durante as primeiras doze horas do puerpério. A freqüência cardíaca aumentou progressivamente durante o trabalho de parto, diminuindo nas primeiras 12 horas após o parto. Quando a pressão arterial e a freqüência cardíaca foram avaliadas conforme o tipo de procedimento anestésico empregado, ambas mostraram-se com mesmo comportamento na anestesia local e peridural, embora naquelas submetidas à anestesia subaracnóidea, tanto a pressão arterial sistólica como a diastólica não apresentaram alteração durante o trabalho de parto. CONCLUSÕES: o trabalho de parto determinou aumento da pressão arterial sistólica e da freqüência cardíaca. Durante o trabalho de parto os valores das pressões arteriais sistólica e diastólica foram mais altos que nas primeiras 12 horas do puerpério, havendo queda significativa entre a primeira e a décima segunda hora do mesmo. Diferentes procedimentos anestésicos não interferiram nos valores das pressões arteriais sistólica e diastólica ou da freqüência cardíaca, durante o trabalho de parto e nas primeiras doze horas após o parto.<br>OBJECTIVE: to analyze the maternal blood pressure and heart rate variation of primigravid women during labor and early puerperium. METHODS: sixty primigravid women were included in the study, and submitted to ambulatory blood pressure monitoring (ABPM) with SpaceLabs 90207 monitor during labor and the first 12 h of puerperium. The records of blood pressure and heart rate were done every 15 min during labor and every 30 min during the first 12 h of puerperium. Three periods during labor (until cervix dilated 7 cm, cervix dilated between 8 cm and total dilatation, and delivery period) and two during puerperium (first and twelfth hours), were analyzed. First of all the results were analyzed without considering the kind of analgesia used and then the patients were divided into three groups, according to the anesthetic technique: local, lumbar extradural or subarachnoid. Results were analyzed by one-way analysis of variance (ANOVA) and paired Student's t-test for blood pressure and heart rate in each group during labor and puerperium. The nonpaired Student's t-test was used to compare different groups. A p value < 0.05 was regarded as statistically significant. RESULTS: when the results were analyzed without considering the analgesic procedure, the values of systolic blood pressure during labor were significantly higher than in early puerperium. During labor, systolic blood pressure values were higher in the periods of later cervical dilatation and delivery than during early cervical dilatation. In the 12th h of puerperium the systolic blood pressure was lower than in the first hour. Diastolic blood pressure did not change during labor and was higher than in early puerperium. Heart rate increased during labor and decreased during puerperium. The systolic and diastolic blood pressure and heart rate were the same both in local or lumbar extradural anesthesia groups; however, in the subarachnoid group the systolic and diastolic blood pressure did not change during labor. CONCLUSIONS: labor increased systolic blood pressure and heart rate. During labor, systolic and diastolic blood pressure were higher than in early puerperium. Both blood pressure and heart rate significantly fell from the first to the 12th hour of puerperium. The different anesthetic techniques did not affect blood pressure or heart rate, as compared with the primigravid group when the anesthetic technique was not taken into consideration.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, M. M. E. (2004). Pressão arterial e freqüência cardíaca avaliadas pela MAPA em primigestas durante o trabalho de parto e puerpério imediato Blood pressure and heart rate evaluated by ABPM in primigravid women during labor and early puerperium. https://doi.org/10.1590/S0100-72032004000500008

MLA

al, Milton Marchioli et. "Pressão arterial e freqüência cardíaca avaliadas pela MAPA em primigestas durante o trabalho de parto e puerpério imediato Blood pressure and heart rate evaluated by ABPM in primigravid women during labor and early puerperium." 2004. https://doi.org/10.1590/S0100-72032004000500008.

Chicago

al, Milton Marchioli et. 2004. "Pressão arterial e freqüência cardíaca avaliadas pela MAPA em primigestas durante o trabalho de parto e puerpério imediato Blood pressure and heart rate evaluated by ABPM in primigravid women during labor and early puerperium.". https://doi.org/10.1590/S0100-72032004000500008.

Harvard

al, M. M. E. 2004, Pressão arterial e freqüência cardíaca avaliadas pela MAPA em primigestas durante o trabalho de parto e puerpério imediato Blood pressure and heart rate evaluated by ABPM in primigravid women during labor and early puerperium, Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, available at: https://doi.org/10.1590/S0100-72032004000500008 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Pressão arterial e freqüência cardíaca avaliadas pela MAPA em primigestas durante o trabalho de parto e puerpério imediato Blood pressure and heart rate evaluated by ABPM in primigravid women during labor and early puerperium
Autore / collaboratori
Milton Marchioli et al
Editore
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
Anno di pubblicazione
2004
ISSN
0100-7203
ISSN
0100-7203
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato