Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Impact of equipment and handling on systolic blood pressure measurements in conscious dogs in an animal hospital environment

Maria Lyberg et al · Oxford University Press · 2021

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

Questa pubblicazione seriale contiene 149 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Abstract Background Situational hypertension and differences between devices complicate interpretations of systolic blood pressure (SBP) measurements in dogs. Hypothesis/Objectives To evaluate if time point of in‐clinic SBP measurement, type of oscillometric device, and operator affect SBP measurements in conscious dogs. Animals Sixty‐seven privately owned dogs with or without chronic kidney disease, divided into 2 study samples (A and B). Methods Cross‐sectional diagnostic study. In part A, SBP measurements in dogs were performed using 2 different devices (HDO and petMap) after acclimatization at 3 standardized time points during a clinical visit. In part B, SBP measurements (HDO) were performed in dogs by a trained final year veterinary student and by the owner alone, at the same occasion. Results For all dogs, there was no difference in mean SBP (mSBP) among the 3 time points for HDO (P = .12) or petMAP (P = .67). However, intraindividual mSBP differences of up to 60 mm Hg between time points were documented. Mean SBP obtained with petMAP was on average 14 (95% CI: 8‐20) mm Hg higher than mSBP obtained with HDO, and this difference increased with increasing SBP. Mean SBP measurements obtained by the trained student were 7 (95% CI: 2‐11) mm Hg higher than mSBP measurements obtained by the owner. Conclusions and Clinical Importance According to the results of this study, time point of in‐clinic SBP measurement in dogs is of minor importance, and instructing owners to perform measurements might reduce suspected situational hypertension. Differences in mSBP measured with HDO and petMAP underscore the need for validation of BP devices used clinically.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, M. L. E. (2021). Impact of equipment and handling on systolic blood pressure measurements in conscious dogs in an animal hospital environment. https://doi.org/10.1111/jvim.16062

MLA

al, Maria Lyberg et. "Impact of equipment and handling on systolic blood pressure measurements in conscious dogs in an animal hospital environment." 2021. https://doi.org/10.1111/jvim.16062.

Chicago

al, Maria Lyberg et. 2021. "Impact of equipment and handling on systolic blood pressure measurements in conscious dogs in an animal hospital environment.". https://doi.org/10.1111/jvim.16062.

Harvard

al, M. L. E. 2021, Impact of equipment and handling on systolic blood pressure measurements in conscious dogs in an animal hospital environment, Oxford University Press, available at: https://doi.org/10.1111/jvim.16062 [Accessed 10 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Impact of equipment and handling on systolic blood pressure measurements in conscious dogs in an animal hospital environment
Autore / collaboratori
Maria Lyberg et al
Editore
Oxford University Press
Anno di pubblicazione
2021
ISSN
0891-6640
ISSN
0891-6640
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato