Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo

Comparison of supervised machine learning algorithms for waterborne pathogen detection using mobile phone fluorescence microscopy

Ceylan Koydemir Hatice et al · Wiley · 2017

Material complementario disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

DOAJ DOAJ Articles
Entrar por DOAJ
Acceso principal

Material complementario disponible

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Abrir material

Resumen

Descripción general del contenido del recurso.

Giardia lamblia is a waterborne parasite that affects millions of people every year worldwide, causing a diarrheal illness known as giardiasis. Timely detection of the presence of the cysts of this parasite in drinking water is important to prevent the spread of the disease, especially in resource-limited settings. Here we provide extended experimental testing and evaluation of the performance and repeatability of a field-portable and cost-effective microscopy platform for automated detection and counting of Giardia cysts in water samples, including tap water, non-potable water, and pond water. This compact platform is based on our previous work, and is composed of a smartphone-based fluorescence microscope, a disposable sample processing cassette, and a custom-developed smartphone application. Our mobile phone microscope has a large field of view of ~0.8 cm2 and weighs only ~180 g, excluding the phone. A custom-developed smartphone application provides a user-friendly graphical interface, guiding the users to capture a fluorescence image of the sample filter membrane and analyze it automatically at our servers using an image processing algorithm and training data, consisting of >30,000 images of cysts and >100,000 images of other fluorescent particles that are captured, including, e.g. dust. The total time that it takes from sample preparation to automated cyst counting is less than an hour for each 10 ml of water sample that is tested. We compared the sensitivity and the specificity of our platform using multiple supervised classification models, including support vector machines and nearest neighbors, and demonstrated that a bootstrap aggregating (i.e. bagging) approach using raw image file format provides the best performance for automated detection of Giardia cysts. We evaluated the performance of this machine learning enabled pathogen detection device with water samples taken from different sources (e.g. tap water, non-potable water, pond water) and achieved a limit of detection of 12 cysts per 10 ml, an average cyst capture efficiency of ~79%, and an accuracy of ~95%. Providing rapid detection and quantification of waterborne pathogens without the need for a microbiology expert, this field-portable imaging and sensing platform running on a smartphone could be very useful for water quality monitoring in resource-limited settings.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, C. K. H. E. (2017). Comparison of supervised machine learning algorithms for waterborne pathogen detection using mobile phone fluorescence microscopy. https://doi.org/10.1515/nanoph-2017-0001

MLA

al, Ceylan Koydemir Hatice et. "Comparison of supervised machine learning algorithms for waterborne pathogen detection using mobile phone fluorescence microscopy." 2017. https://doi.org/10.1515/nanoph-2017-0001.

Chicago

al, Ceylan Koydemir Hatice et. 2017. "Comparison of supervised machine learning algorithms for waterborne pathogen detection using mobile phone fluorescence microscopy.". https://doi.org/10.1515/nanoph-2017-0001.

Harvard

al, C. K. H. E. 2017, Comparison of supervised machine learning algorithms for waterborne pathogen detection using mobile phone fluorescence microscopy, Wiley, available at: https://doi.org/10.1515/nanoph-2017-0001 [Accessed 5 Aug. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Comparison of supervised machine learning algorithms for waterborne pathogen detection using mobile phone fluorescence microscopy
Autor / colaboradores
Ceylan Koydemir Hatice et al
Editorial
Wiley
Año de publicación
2017
ISSN
2192-8606
ISSN
2192-8606
Idioma
Inglés

Materias

Explorá otros recursos relacionados a partir de estas materias.

Copiado