Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Study of the heat transfer efficiency of a wick heat pipe with induction heating of the core made of magnetic stainless steel

Iryna Vashchyshak et al · Vasyl Stefanyk Carpathian National University · 2025

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

The results of mathematical modelling of a heat pipe with induction heating of the core, designed for efficient transfer of low-temperature heat flow to the working fluid in conditions of limited dimensions, are presented. The design includes a thin-walled copper casing, a porous wick structure made of non-magnetic stainless steel mesh, and a magnetic stainless steel core heated by a cylindrical induction coil placed on the casing above the core. Based on physical models of heat transfer, a mathematical description of the processes has been developed that takes into account induction heat generation, the heat capacity of the tube components, and heat losses due to free convection. The dependence of the heating dynamics and thermal efficiency on the angle of inclination of the heat pipe relative to the vertical has been established. The results of the calculations showed that maximum efficiency is achieved in a vertical position, and with an increase in the angle of inclination above 60°, there is an increase in gravitational resistance to fluid motion, which leads to a gradual decrease in heat transfer. It has been shown that at inclinations up to 80°, the performance of the structure is maintained, but to ensure stable operation at even greater angles, additional measures are necessary: reducing the radius of the pores of the wick structure to increase capillary pressure, increasing the thickness or number of mesh layers, and selecting working fluids with more favourable wetting properties.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, I. V. E. (2025). Study of the heat transfer efficiency of a wick heat pipe with induction heating of the core made of magnetic stainless steel. https://doi.org/10.15330/pcss.26.3.613-621

MLA

al, Iryna Vashchyshak et. "Study of the heat transfer efficiency of a wick heat pipe with induction heating of the core made of magnetic stainless steel." 2025. https://doi.org/10.15330/pcss.26.3.613-621.

Chicago

al, Iryna Vashchyshak et. 2025. "Study of the heat transfer efficiency of a wick heat pipe with induction heating of the core made of magnetic stainless steel.". https://doi.org/10.15330/pcss.26.3.613-621.

Harvard

al, I. V. E. 2025, Study of the heat transfer efficiency of a wick heat pipe with induction heating of the core made of magnetic stainless steel, Vasyl Stefanyk Carpathian National University, available at: https://doi.org/10.15330/pcss.26.3.613-621 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Study of the heat transfer efficiency of a wick heat pipe with induction heating of the core made of magnetic stainless steel
Autore / collaboratori
Iryna Vashchyshak et al
Editore
Vasyl Stefanyk Carpathian National University
Anno di pubblicazione
2025
ISSN
1729-4428
ISSN
1729-4428
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato