Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Use of contrast‐enhanced computed tomography to detect kidney infarction in dogs

Somchin Sutthigran et al · Oxford University Press · 2022

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

Questa pubblicazione seriale contiene 149 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Abstract Background Kidney infarction is a renovascular disease diagnosed by contrast‐enhanced computed tomography (CECT) in humans. Objectives To describe the frequency of kidney infarction and to determine the detection of kidney infarction with CECT in dogs. Animals Eight hundred and twenty‐six abdominal CECT studies of 826 dogs. Methods A cross‐sectional retrospective study. Dogs with abdominal CT scans including CECT were retrospectively retrieved. Kidney infarction was classified into 3 grades based on the extent of infarction relative to total kidney area. The location and number of kidney infarctions in each kidney were expressed as number and percentage. The ability of visualization of kidney infarction in each multiplanar reconstruction (MPR) image plane was evaluated by agreement of 2 observers. Results The frequency of kidney infarction in dogs was 3.15% (26/826 dogs; 95% CI = 2.05‐4.61). Most kidney infarctions were classified as grade 1, or the lesions were less than 25% of the kidney (47/56, 83.93%) and most were detected at the caudal pole of the kidney (31/56, 55.35%) on the sagittal plane. On MPR image planes, the sagittal plane had the highest proportion (34/56, 60.71%) of excellent visual category to detect kidney infarction. Conclusions and Clinical Importance The CECT, especially the sagittal plane, is a useful diagnostic tool for the detection of kidney infarction in dogs.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, S. S. E. (2022). Use of contrast‐enhanced computed tomography to detect kidney infarction in dogs. https://doi.org/10.1111/jvim.16343

MLA

al, Somchin Sutthigran et. "Use of contrast‐enhanced computed tomography to detect kidney infarction in dogs." 2022. https://doi.org/10.1111/jvim.16343.

Chicago

al, Somchin Sutthigran et. 2022. "Use of contrast‐enhanced computed tomography to detect kidney infarction in dogs.". https://doi.org/10.1111/jvim.16343.

Harvard

al, S. S. E. 2022, Use of contrast‐enhanced computed tomography to detect kidney infarction in dogs, Oxford University Press, available at: https://doi.org/10.1111/jvim.16343 [Accessed 10 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Use of contrast‐enhanced computed tomography to detect kidney infarction in dogs
Autore / collaboratori
Somchin Sutthigran et al
Editore
Oxford University Press
Anno di pubblicazione
2022
ISSN
0891-6640
ISSN
0891-6640
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato