Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Which mode and potency of electrocoagulation yields the Smallest Unobstructed Area of the Fallopian Tubes?

Marcelo Ivo Campagnolo et al · Federação Brasileira das Sociedades de Ginecologia e Obstetrícia · 2018

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A FEBRASGO e o Novo Ano

Questa pubblicazione seriale contiene 195 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Abstract Objective To determine which mode and potency of electrocoagulation, using a modern electrosurgical generator, yields the smallest unobstructed area of the Fallopian tubes. Methods In an experimental study, tubes from 48 hysterectomies or tubal ligation were evaluated. Tubes were randomly allocated to one of the following groups: group A) 25 W x 5 seconds (n = 17); group B) 30 W x 5 seconds (n = 17); group C) 35 W x 5 seconds (n = 18), group D) 40 W x 5 seconds (n = 20); group E) 40 W x 5 seconds with visual inspection (blanch, swells, collapse) (n = 16); group F) 50 W x 5 seconds (n = 8). Bipolar electrocoagulation was performed in groups A to E, and monopolar electrocoagulation was performed in group F. Coagulation mode was used in all groups. Digital photomicrography of the transversal histological sections of the isthmic segment of the Fallopian tube were taken, and themedian percentage of unobstructed luminal area (mm2) was measured with ImageJ software (ImageJ, National Institutes of Health, Bethesda, MD, USA). The Kruskal-Wallis test or analysis of variance (ANOVA) was used for statistical analysis. Results Ninety-six Fallopian tube sections were analyzed. The smallest median occluded area (%; range) of the Fallopian tube was obtained in the group with 40 W with visual inspection (8.3%; 0.9-40%), followed by the groups 25 W (9.1%; 0-35.9%), 40 W (14.2; 0.9-43.2%), 30 W (14.2; 0.9-49.7%), 35 W (15.1; 3-46.4%) and 50 W (38.2; 3.1-51%). No statistically significant difference was found among groups (p = 0.09, Kruskal-Wallis test). Conclusion The smallest unobstructed area was obtained with power setting at 40 W with visual inspection using a modern electrosurgical generator. However, no statistically significant difference in the unobstructed area was observed among the groups using these different modes and potencies.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, M. I. C. E. (2018). Which mode and potency of electrocoagulation yields the Smallest Unobstructed Area of the Fallopian Tubes?. https://doi.org/10.1055/s-0038-1656718

MLA

al, Marcelo Ivo Campagnolo et. "Which mode and potency of electrocoagulation yields the Smallest Unobstructed Area of the Fallopian Tubes?." 2018. https://doi.org/10.1055/s-0038-1656718.

Chicago

al, Marcelo Ivo Campagnolo et. 2018. "Which mode and potency of electrocoagulation yields the Smallest Unobstructed Area of the Fallopian Tubes?.". https://doi.org/10.1055/s-0038-1656718.

Harvard

al, M. I. C. E. 2018, Which mode and potency of electrocoagulation yields the Smallest Unobstructed Area of the Fallopian Tubes?, Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, available at: https://doi.org/10.1055/s-0038-1656718 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Which mode and potency of electrocoagulation yields the Smallest Unobstructed Area of the Fallopian Tubes?
Autore / collaboratori
Marcelo Ivo Campagnolo et al
Editore
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
Anno di pubblicazione
2018
ISSN
0100-7203
ISSN
0100-7203
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato