Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo

Avaliação da condutividade hidraulica do solo saturada utilizando dois métodos de laboratório numa topossequência com diferentes coberturas vegetais no Baixo Amazonas Evaluation of the saturated hydraulic conductivity using two laboratory methods in a topossequence with different vegetation cover in the lower Amazon

Jean Dalmo de Oliveira Marques et al · Instituto Nacional de Pesquisas da Amazônia · 2008

Material complementario disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.
Publicación seriada

"Pinta" em população nativa do Estado do Amazonas

Esta publicación seriada contiene 218 contenidos relacionados.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

DOAJ DOAJ Articles
Entrar por DOAJ
Acceso principal

Material complementario disponible

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Abrir material

Resumen

Descripción general del contenido del recurso.

O objetivo desse trabalho foi avaliar dois métodos de laboratório para a determinação da condutividade hidráulica do solo saturada (Ko) conhecidos como Permeâmetro de carga constante (PCC) e Permeâmetro de carga decrescente (PCD), com o intuito de verificar sua aplicabilidade e variabilidade em solos amazônicos. Coletaram-se 125 amostras de solo com estrutura indeformada, através de amostrador tipo Uhland, com anéis volumétricos, de 0,072 m de altura e 0,069 m de diâmetro, devido à variabilidade apresentada pelas determinações de tal parâmetro. Nos mesmos pontos de amostragens da Ko, procedeu-se coleta de anéis volumétricos para a determinação da porosidade do solo. Ainda nesses pontos foram coletadas amostras com estrutura deformada para análises físicas e químicas. Os resultados obtidos demonstram que o método do PCC foi o mais apropriado para a classe dos Latossolos estudados, apresentando os menores coeficientes de variação e desvio padrão ao longo da topossequência. Os valores de Ko estiveram distribuídos entre P1(2,65 à 3,34 cm dia-1), P2(2,85 à 3,38 cm dia-1), P3(2,86 à 3,63 cm dia-1), P4(2,75 à 3,49 cm dia-1), P5(2,38 à 3,83 cm dia-1) e P6 (2,47 à 3,52 cm dia-1); havendo uma tendência para maiores valores de Ko na superficie. A utilização de Ko como parâmetro de análise hídrica em solos porosos na superfície e muito argilosos em profundidade, como os amazônicos, necessita ser realizada com precaução, evitando a interrupção da continuidade dos poros e compactação da amostra. Mudanças na condutividade hidráulica saturada estiveram mais relacionadas a alterações nas propriedades físicas do solo e posição no relevo do que nas alterações das coberturas vegetais ao longo da topossequência.<br>The objective of this work was to evaluate two different laboratory methods for determining the saturated hydraulic conductivity (Ko), namely, the constant head permeameter method (PCC) and the falling decreasing head permeameter method (PCD) and their applicability and variability to Amazon soils. 125 undisturbed soil samples were collected with an Uhland soil sampler using volumetric rings of 0,072 m height and 0,069 m in diameter. Soil porosity was also estimated by volumetric ring samples collected at the same spots where Ko was evaluated. Disturbed soil samples were also collected for chemical and particle size analysis at the same spots. The results showed that the PCC method was more appropriate for the studied soils Oxisols, leading to the lowest coefficient of variation and standard deviation throughout the topographic sequence. The Ko values were distributed among P1(2,65 to 3,34 cm day-1), P2(2,85 to 3,38 cm day-1), P3(2,86 to 3,63 cm day-1), P4(2,75 to 3,49 cm day-1), P5(2,38 to 3,83 cm day-1) and P6 (2,47 to 3,52 cm day-1); having a tendency to show higher Ko values at soil surface. The use of Ko as a parameter for hydraulic analysis in soils with high porosity in the surface layer and high clay content in the subsoil, as is the case in the Amazon, must be undertaken with caution to avoid compacting the sample and porous discontinuities. Throughout the studied topographic sequence, changes of saturated hydraulic conductivity were more related to changes in soil physical properties than to changes in vegetation cover throughout the studied topographic sequence.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, J. D. D. O. M. E. (2008). Avaliação da condutividade hidraulica do solo saturada utilizando dois métodos de laboratório numa topossequência com diferentes coberturas vegetais no Baixo Amazonas Evaluation of the saturated hydraulic conductivity using two laboratory methods in a topossequence with different vegetation cover in the lower Amazon. https://doi.org/10.1590/S0044-59672008000200002

MLA

al, Jean Dalmo de Oliveira Marques et. "Avaliação da condutividade hidraulica do solo saturada utilizando dois métodos de laboratório numa topossequência com diferentes coberturas vegetais no Baixo Amazonas Evaluation of the saturated hydraulic conductivity using two laboratory methods in a topossequence with different vegetation cover in the lower Amazon." 2008. https://doi.org/10.1590/S0044-59672008000200002.

Chicago

al, Jean Dalmo de Oliveira Marques et. 2008. "Avaliação da condutividade hidraulica do solo saturada utilizando dois métodos de laboratório numa topossequência com diferentes coberturas vegetais no Baixo Amazonas Evaluation of the saturated hydraulic conductivity using two laboratory methods in a topossequence with different vegetation cover in the lower Amazon.". https://doi.org/10.1590/S0044-59672008000200002.

Harvard

al, J. D. D. O. M. E. 2008, Avaliação da condutividade hidraulica do solo saturada utilizando dois métodos de laboratório numa topossequência com diferentes coberturas vegetais no Baixo Amazonas Evaluation of the saturated hydraulic conductivity using two laboratory methods in a topossequence with different vegetation cover in the lower Amazon, Instituto Nacional de Pesquisas da Amazônia, available at: https://doi.org/10.1590/S0044-59672008000200002 [Accessed 5 Aug. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Avaliação da condutividade hidraulica do solo saturada utilizando dois métodos de laboratório numa topossequência com diferentes coberturas vegetais no Baixo Amazonas Evaluation of the saturated hydraulic conductivity using two laboratory methods in a topossequence with different vegetation cover in the lower Amazon
Autor / colaboradores
Jean Dalmo de Oliveira Marques et al
Editorial
Instituto Nacional de Pesquisas da Amazônia
Año de publicación
2008
ISSN
0044-5967
ISSN
0044-5967
Idioma
Inglés

Materias

Explorá otros recursos relacionados a partir de estas materias.

Copiado